User Setup - Set Menu - GE ZTS Series Operation And Maintenance

Transfer switches 40-4000 amps
Table of Contents

Advertisement

Entelli-Switch 250 User Setup - SET Menu
S1 O K
01: 50
F R I 3 1 MAY 20 03
M OR E
T E ST
1 VA B = _ _ _
2 VAB = _ __
V B C = ___
V BC = __ _
VC A = ___
VCA = __ _
M O R E
C F G
S ET
ESC
S E T
US E R S E T UP
M OR E
BACK
—SET SYSTEM CLOCK (pg.13)
—DAYLIGHT SAVINGS ON/OFF
—CLOCK EXERCISER (CDP)
(pg.10 & 15)
—EXER S2 RUNTIME (CDT)
(pg.10 & 14)
—S1 UNDER VOLTAGE (pg.8)
Fail
Restore
—S1 UNDER FREQUENCY (pg.8)
Fail
Restore
—S1 OVER VOLTAGE (pg.11)
Fail
Restore
—S1 OVER FREQUENCY (pg.8)
Fail
Restore
—S2 UNDER VOLTAGE (pg.8)
Fail
Restore
—S2 UNDER FREQUENCY (pg.8)
Fail
Restore
—S2 OVER VOLTAGE (pg.8)
Fail
Restore
—S2 OVER FREQUENCY (pg.8)
Fail
Restore
—SET % PHASE IMBALANCE (VI)
FAIL 5%, RESTORE 3% (pg.13)
—SET PHASE IMBALANCE (VI)
TIME DELAY 30 seconds (pg.13)
GE Zenith Controls
Change adjustable values
through the SET menu.
Enter six digit access code
(The factory assigned six-digit access code
is located on the back of the controller)
J2
J4
—TIME DELAY S2 START (P1)
(pg.11)
—TIME DELAY S2 STABLE (W)
(pg.13)
—LOAD PRESIGNAL TD (T3/W3)
(pg.12)
—LOAD DISCONNECT TD (UMD)
(pg.13)
—ATS OPEN TIME TO S2 (DW)
DELAY units only (pg.10)
—TIME DELAY S1 STABLE (T) (pg.12)
—ATS OPEN TIME TO S1 (DT)
DELAY units only (pg.10)
—S2 STOP DELAY (U) (pg.12)
—CALIBRATE S1 (pg.10)
—CALIBRATE S2 (pg.10)
Optional Accessories
ZTS / ZTSD Operation and Maintenance Manual (71R-3000)
WARNING
1
Controller inputs must be relay isolated.
{
Customer
Network Communications
Input
(Option)
Voltage
*
1
PROG 1
J2-3
2
PROG 2
3
GRD (Input Sink)
4
2
Controller ouputs have limited source capability.
LS OUT
Use only GE Zenith - specified output modules.
5
NIA OUT
6
ELEV. PRE. OUT
{
5
11
7
6
Output Contacts
12
7
ALARM OUT
13
8
STE OUT
{
8
14
9
9
Output Contacts
15
10
16
10
MOTOR DISC. OUT
11
12
TMS IN
13
11
INHIB. > S1
14
INHIB. > S2
12
R1
15
Output
LS IN
16
13
14
* Input and output availability
subject to factory configuration.
15
R2
Output
*
16
1
2
Contact Rating: 10A @ 277VAC or 30VDC
3
+12V (Output Source)
4
LN OUT
Lithium Battery
5
L4 OUT
6
L3 OUT
7
L2 OUT
8
L1 OUT
User Access Code
9
YN IN
10
YE IN
Product Information
11
TSNL IN
24-Hour Service
12
Q2/TSL IN
13
S12 IN
14
S5 IN
Entelli-Switch 250
Figure 10
N.O.
N.C.
To J2/J4 Input
1
From J2/J4
2
Output
R1
3
4
J4-3
R2
5
6
R1
Output
7
8
9
R2
Output
10
Exerciser Battery
Replacement - K-4100 (BR2032)
+
Service Life - 10 Years
+
During normal operation
Default - 121212
www.geindustrial.com
(773) 299-6600
TM
17