gtc400c_BUCH-3220-004.book Seite 8 Mittwoch, 9. Mai 2018 9:19 09
8 | English
Thermal imaging camera
Integrated visual camera
Batteries (alkali-manganese)
Battery pack (lithium-ion)
USB port
Real Time Clock Power Supply
– Button cell
– Battery service life, approx.
Wireless connectivity
Max. WiFi transmission power
WiFi operating frequency range
Weight according to EPTA-Procedure 01:2014
Dimensions (length x width x height)
Degree of protection (excluding battery compartment)
Permitted environmental conditions
– Charging temperature
2)
– Operating temperature
– Storage temperature
– Relative humidity (non-condensing)
Recommended batteries
Recommended chargers
The measuring tool can be clearly identified with the serial number 2 on the type plate.
1) at an ambient temperature of 20–23 °C and an emissivity of >0.999, measuring distance: 0.3 m, operating time: >5 min
2) limited performance at temperatures <0 °C
Technical data determined with battery from delivery scope.
Assembly
Power Supply
The measuring tool can be operated using either commercial-
ly available batteries (LR6 AA batteries or similar) or using a
Bosch Li-ion rechargeable battery.
Operation with Battery Adapter (Removable)
(see figure A)
The batteries are inserted into the battery adapter.
 The non-rechargeable battery adapter is intended only
for use in designated Bosch measuring tools and must
not be used with power tools.
To insert the batteries, slide the cover of the battery adapter
21 into the battery port 18. Place the batteries in the cover as
per the illustration on the sealing cap 20. Slide the sealing cap
over the cover until you feel it click into place and it is flush
with the handle of the measuring tool.
1 609 92A 4FJ | (9.5.18)
4 x 1.5 V LR6 (AA) (with battery adapter)
CR2450 (3 V lithium battery)
To remove the batteries, press the release buttons
19 of the sealing cap 20 and pull off the sealing
cap. In doing so, make sure that the batteries do
not fall out. To do this, hold the measuring tool with
the battery port 18 facing upwards. Remove the
batteries. To remove the inside cover 21 from the
battery port 18, reach into the cover recess 22 and pull it out
of the measuring tool by applying light pressure to the side
wall (see figure B).
Note: Do not use any tools (e.g. a screwdriver) to remove the
battery, as this could break the casing.
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
 Remove the batteries from the measuring tool when
not using it for extended periods. When storing for ex-
tended periods, the batteries can corrode and self-dis-
charge.
GTC 400 C
10.8 V/12 V
1.1
60 months
WiFi
30 mW
2.400–2.483 GHz
0.54 kg
233 x 95 x 63 mm
IP 53
0...+45 °C
–10...+45 °C
–20...+70 °C
20... 80 %
GBA 10,8 V
GBA 12 V
AL 11.. CV
GAL 12.. CV
Bosch Power Tools