Download Print this page

Honeywell V5832B Product Data

Small linear valves pn16

Advertisement

Quick Links

V5832B
GENERAL
These small linear valves are used in combination with small
electric linear valve actuators for the control of hot and/or
chilled water for fan coil units, small reheaters/recoolers in
electric/electronic temperature control systems. Because of
the pressure-balanced plug, the close-off pressure is equal to
the system pressure.
® U.S. Registered Trademark
Copyright © 2012 Honeywell Inc. • All rights reserved
V5833A
V5832B/V5833A
Small Linear Valves PN16
FEATURES
Pressure balanced plug
Range of fittings available for different connections
Easy to mount, no tools required
Flat sealing connections
Flat surfaces on body to fit installation tools
Standard external threads for Honeywell or field
supplied fittings
Adjustment cap for manual operation

SPECIFICATIONS

Model
Operation
Nominal pressure rating
Capacity index (k
)
VS
Leakage rate
Valve body:
Material
Size
Trim:
Stem
Plug
Suitable medium
Controlled water
temperature:
Rangeability
Flow characteristic
Stroke
Dimensions
PRODUCT DATA
Two-way: V5832B
Three-way: V5833A
Stem up to close port A to AB
PN16
see tables on page 2
0.05% of k
VS
Brass resistant to dezincification
DN25 (1"), DN32 (11/4"),
DN40 (11/2")
Stainless steel
Brass
Water, with max. 50% glycol
2...130C
50:1
Linear for port A-AB,
linear for bypass port B-AB
6.5 mm
see Fig. 3 on page 4
EN0B-0408GE51 R0612

Advertisement

loading

Summary of Contents for Honeywell V5832B

  • Page 1: Specifications

    2...130C Rangeability 50:1 Flow characteristic Linear for port A-AB, linear for bypass port B-AB Stroke 6.5 mm Dimensions see Fig. 3 on page 4 ® U.S. Registered Trademark EN0B-0408GE51 R0612 Copyright © 2012 Honeywell Inc. • All rights reserved...
  • Page 2 V5832B/V5833A SMALL LINEAR VALVES PN16 – PRODUCT DATA FLOW CAPACITIES AND CLOSE OFF PRESSURE RATINGS TWO-WAY VALVES close-off pressure (= max. operating close-off pressure (= max. operating order no. pressure) in kPa for 300-N actuators pressure) in kPa for 400-N actuators...
  • Page 3 25 to 30 Nm. The valve is supplied complete with mounting instructions. The water quality should meet VDI 2035 requirements. ACCESSORIES Valves V5832B need two connection sets, valves V5833A need three connection sets. Connection Pipe Size Order Number Connection Set Description R1"...
  • Page 4 Fig. 3. Dimensions (in mm) Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17...

This manual is also suitable for:

V5833a