Download Print this page
Honeywell S4567A 1001 Instruction Sheet

Honeywell S4567A 1001 Instruction Sheet

Ignition control for combined valve and ignition system

Advertisement

Quick Links

IGNITION CONTROL FOR COMBINED VALVE AND IGNITION SYSTEM
APPLICATION
The Combined Valve and Ignition system (CVI) has specially
been developed for application in gas fired appliances with
either intermittent pilot or direct burner ignition.
For this system, the S4567A 1001 and S4567B 1017 ignition
controls have been designed to attach directly onto the
VK4105 gas controls.
The combined system then provides programmed safe light
up, flame supervision and regulation of gas flow to the main
burner.
DESCRIPTION
The S4567A 1001 and S4567B 1017 ignition controls provide
automatic ignition for direct gas burner applications.
The S4567A 1001 and S4567B 1017 ignition controls comply
with EN 55014 and function in accordance with:
-- EN 298, code A/M/C/L/X/N.
-- ANSI Z21.20
FEATURES
 Flame supervision.
 Built in 33 Hz or 40 Hz ignition.
 External reset and alarm.
 Accurate safety timer.
 Supply voltages of 220 ... 240 V in a single product.
 Full operating sequence after flame loss.
 Safe separation opto couplers for flame output
(S4567B 1017 only), alarm output and reset input.
 Non volatile lock--out according EN 298.
 Gas valve live output (S4567A 1001 only).
 Flame rod safely accessible because of protective
impedance.
S4567A 1001 & S4567B 1017

SPECIFICATIONS

Model
S4567A 1001 ignition control for atmospheric, direct
S4567B 1017 ignition control for atmospheric, direct
Supply voltage
220 ... 240 Vac, 50 ... 60 Hz
Power consumption
4 VA
Humidity
90% RH max. at 40 _C (non condensing)
Ambient temperature
--15 ... 60 _C
Electrical rating
Gas valve output (pin 2 of S4567A 1001): suitable for one
VK4105. Use rectifier plug from the 45.900.441--"series ",
e. g. 45.900.441--030
Electrical connection
High voltage spark: 2.8 x 0.5 mm spade terminal
Flame sensing: 4.8 x 0.8 mm spade terminal
PCB connector: Stocko mks 2823 3 and 4 pole
IP protection degree in accordance with EN 60529
IP 00 (standard)
IP 04 or IP X4
Use: cover set 45.900.431--004 or
IP 44
As IP 04 but the appliance manufacturer must connect the
ignition output in such a way that it cannot be taken off
without the use of a tool.
In order to prevent the risk of an electric shock when the
ignition control is mounted in the appliance, additional
protection of the ignition output must be provided by the
application manufacturer in all above cases.
Timing
Self check time (T
Safety time (T
Flame sensing
Min. flame current: 0.9 ←A
Response time on: > 0.2 s
Response time off at I
burner ignition.
burner ignition and flame opto output
cover set 45.900.431--005
(flame retardant according to UL94--V0)
cable grommet 45.900.442--008/009
sleeve 45.900.442--003
gasket 45.900.442--007/011
): 1.5 s
c
): 10 s
s
= 2 ←A : < 1 s
flame
INSTRUCTION SHEET
EN1R--9132 0011R7--NE

Advertisement

loading

Summary of Contents for Honeywell S4567A 1001

  • Page 1: Specifications

    --15 ... 60 _C APPLICATION Electrical rating Gas valve output (pin 2 of S4567A 1001): suitable for one The Combined Valve and Ignition system (CVI) has specially VK4105. Use rectifier plug from the 45.900.441--“series “, been developed for application in gas fired appliances with e.
  • Page 2 SYSTEM OPERATION S4567A 1001 and S4567B 1017 (see fig. 3.) When there is a call for heat a self check time (T ) plus waiting period (T ) elapse before built--in igniter and gas valve(s) are switched on.
  • Page 3 LM -- Limiter RS -- Reset switch Fig. 2. Connection diagram S4567B 1017 Legend Thermostat Limiter Alarm Ignition Gas valve (and external gas valve (A 1001)) Flame rod Fig. 3. Functional diagram S4567A 1001 and S4567B 1017 EN1R- -9132 0011R7- -NE...
  • Page 4 Under normal circumstances no maintenance or service is Fusing required nor possible. In order to prevent unsafe conditions at too high current, the The S4567A 1001 and S4567B1017 ignition controls are field automatic ignition controls must be externally fused with a replacaeble. 4 A fuse (F).

This manual is also suitable for:

S4567b 1017