Operation With Optional Warning Flash Lamp; Operation With Connected Door Contacts - GE ERESCO MF4 Series Operating Manual

Industry x-ray unit for digital control unit
Table of Contents

Advertisement

Fig. 5 - Plug hutch of the digital control unit ERESCO MF4 control (without cover, without handle)
2.1.1
Operation with optional warning flash lamp
Depending on the available power supply 230 V or 115 V, a warning flash lamp can be
optionally connected optionally to socket X3 .
(Use the supplied eyebolt to remove the short-circuit plug)
NOTE:
2.1.2
Operation with connected door contacts
When the safety door contacts are to be connected, use the supplied eyebolt to remove
the short circuit plug for the door contact from socket X2 at the plug hutch.
NOTE:
Copyright by GE Sensing & Inspection Technologies GmbH
08/24/2016
6. Edition, ID No.: 37020GB-F
Operating Manual ERESCO MF4 Type Series
Earthing Bold
Fuses
F1 and F2
Horn
X5 Radiating unit
With a connected warning flash lamp, an prewarning time of at least 2
seconds m u s t be set, otherwise the high voltage cannot be switched
on.
Short circuit plug
If door contact 1 has been opened, door contact 2 should also be opened.
Both door contacts must be closed before the unit is ready for operation
again.
Short circuit plug with eyebolt
Eyebolt
X2 Door contacts /
X4 Cooling circuit
Potential-free
contacts
X3 Warning flash lamp
Bogenstrasse 41 D - 22926 Ahrensburg
X6 External Start/Stop
X1 Mains connection
15