Maintenance Instructions; Cleaning And Lubrication; Troubleshooting - RIDGID PEX-One Operator's Manual

Electro crimp tool
Table of Contents

Advertisement

any sharp edges that may have formed
on the crimped connection.
7 . When operation is complete, move ON/ -
OFF (I/O) switch to OFF (O) and remove
the battery.
Inspecting the Crimped
Connection
1. Visually inspect crimped connection for:
• Tube not fully inserted.
• Incorrect placement, distortion or de-
formation of crimped sleeve/ring.
• Any other issues per fitting manufac-
turer.
If any issues are found, remove fitting
and install a new connection.
2. Check crimp size as required for system
by fitting manufacturer:
• ASTM F1807 crimped connections are
checked with a GO/NO GO gauge. Us -
ing correct gauge, hold gauge perpen-
dicular to axis of tube. A crimp is good if
GO gauge fits over ring, and NO GO
gauge does not.
Figure 11 – Correct Go Gauge Fit
3. Test connection in accordance connector
manufacturer instructions, normal prac-
tice and applicable codes.

Troubleshooting

PROBLEM
Dies will not open
enough to go over
fitting.
Tool will not turn ON
when ON/OFF switch
is turned ON.
Tool will not operate.
See Figure 5 - Work Light/Status Chart for Light Diagnostic Codes.
085-003-980.10_REV. A
POSSIBLE REASON
The tool is not fully retracted.
Battery is completely discharged or bat-
tery has failed.
Battery not properly inserted into the
tool.
Tool has been run FORWARD (Not fully
retracted.)
PEX-One Crimp Tool
Storage
Remove battery from tool. Store crimp tool
and battery in case. Avoid storing in extreme
heat or cold. The tool will not turn ON if the tool
is outside the specification range. This will be
indicated by the work light (see Figure 5).
Store tool in a dry, secured
WARNING
area that is out of reach of children and people
unfamiliar with the RIDGID PEX-One Crimp
Tool. The Crimp tool is dangerous in the hands
of untrained users.
Maintenance
Instructions
WARNING
Make sure battery is removed from tool
before performing maintenance or mak-
ing any adjustment.

Cleaning and Lubrication

1. After each use, wipe any oil or dirt off
the crimp tool and dies with a clean, dry,
soft cloth.
2. Check jaw lever operation with each use.
Tool head should open and close freely
with only moderate finger effort required.
3. Clean the die crimp profile with steel wool,
steel bristle wire brush, or fine grade
Scotch-Brite
®
(Scotch-Brite is a registered
trademark of the 3M Company). Do not
use aggressive cleaning methods that
may alter critical crimp profile dimensions
(see Figure 7).
4. Tool is lubricated for life from the factory
and does not require any further lubri-
cation.
Press the REVERSE button.
Insert fully charged battery.
Check to assure battery is fully inserted.
Press the REVERSE button.
SOLUTION