Chapter 8 Advanced Copy Status
8.7 Settings (Advanced Copy)
The following items are displayed in the Main area:
Local Storage System Information
Box ID
The Box ID for the local storage system is displayed.
"Box ID" is an identifier used to identify individual storage systems. This ID is a unique name in the user
system and consists of 40-digit code.
The initial Box ID is a device ID consisting of device information (such as series name, model name, and
serial number).
Remote Storage System Information
Box ID
This is the Box ID of the remote storage system that has a path to the local storage system. Click this item
to display the [Copy Path] screen. Refer to
Connection Type
The type of connection to the remote storage system that has a path to the local storage system is
displayed.
-
Direct
-
Remote
Priority Level
REC is performed using the priority level (Automatic Priority/High Priority/Middle Priority/Low Priority/Very
Low Priority) that is specified with the [Modify EC/OPC Priority] function (*1).
-
Automatic
REC is performed using the priority level (Automatic Priority/High Priority/Middle Priority/Low Priority/
Very Low Priority) that is specified using the "Modify REC Multiplicity" function (*1).
-
1 - 8
REC is performed with the displayed priority level. "1" corresponds to "Very Low Priority", and "8"
corresponds to "High Priority" for the [Modify EC/OPC Priority] function (*1).
Multiplicity
When the local storage system and the remote storage system are connected by remote connection, the
multiplicity is displayed. If the "Connection Type" is "Direct", a "-" (hyphen) is displayed.
-
Automatic
REC is performed with the recommended multiplicity that is calculated by the [Measure Round Trip
Time] result (*2).
-
1 - 1024
REC is performed with the multiplicity that is manually specified with the [Modify REC Multiplicity]
function (*3).
Recommended Multiplicity
When the local storage system and the remote storage system are connected by remote connection, the
recommended multiplicity is displayed. If the "Connection Type" is "Direct", a "-" (hyphen) is displayed.
-
1 - 1024
The recommended multiplicity that is calculated by the [Measure Round Trip Time] result (*2).
-
***
The round trip time is not measured by the [Measure Round Trip Time] function (*2).
"8.10 Copy Path Detail" (page 401)
386
ETERNUS Web GUI User's Guide (Operation)
Copyright 2016 FUJITSU LIMITED
for details.