Quick Links

P3AG-1812-06ENZ0
FUJITSU Storage
ETERNUS AF250 S2,
ETERNUS AF250
All-Flash Arrays
Site Planning Guide
Requirements for transportation/installation

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ETERNUS AF250 S2

  • Page 1 P3AG-1812-06ENZ0 FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Requirements for transportation/installation...
  • Page 2: Table Of Contents

    Rack Installation Requirements ....................31 Placement in the Rack ............................31 Cable Connection ..............................32 Installable Racks ........................... 35 Fujitsu Racks .................................35 Non-Fujitsu Racks ..............................35 FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 3 Figure 17 Distance between Each Enclosure and the Power Distribution Unit (Example) ........32 Figure 18 AC Cable Connection..........................33 Figure 19 Unit Installation Area ..........................36 FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 4 List of Tables Table 1 ETERNUS AF250 S2 Installation Specifications ....................7 Table 2 Efficiency and Power Factor of the Power Supply Unit (ETERNUS AF250 S2) ..........8 Table 3 ETERNUS AF250 Installation Specifications....................9 Table 4 Package Size (for Regions other than the EMEIA, Central American, and Caribbean Regions) ....14 Table 5 Current Consumption of Each Power Cord....................17...
  • Page 5 Preface Fujitsu would like to thank you for purchasing the FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 (herein- after referred to as ETERNUS AF). The ETERNUS AF is designed to be connected to Fujitsu servers (Fujitsu SPARC Servers, PRIMEQUEST, PRIMERGY, and other servers) or non-Fujitsu servers.
  • Page 6 - Be careful that no liquid seeps into the ETERNUS storage system when using cleaners, etc. - Do not use alcohol or other solvents to clean the ETERNUS storage system. Warning layout ribbon FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 7: Eternus Af Installation

    AC 100 – 120V 1,600kJ/h AC 200 – 240V 1,600kJ/h Maximum amount of ex- Controller enclosure 4.0m /min haust air Drive enclosure 4.0m /min FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 8: Table 2 Efficiency And Power Factor Of The Power Supply Unit (Eternus Af250 S2)

    *8: These values are measured when a single controller enclosure and a single drive enclosure are configured in an environment in which the temperature is 23 ± 2°C at 0 meters above sea level. Table 2 Efficiency and Power Factor of the Power Supply Unit (ETERNUS AF250 S2) Power fac- Efficiency ®...
  • Page 9: Eternus Af250

    AC 100 – 120V 1,600kJ/h AC 200 – 240V 1,600kJ/h Maximum amount of ex- Controller enclosure 4.0m /min haust air Drive enclosure 4.0m /min FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 10 *8: These values are measured when a single controller enclosure and a single drive enclosure are configured in an environment in which the temperature is 23 ± 2°C at 0 meters above sea level. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED...
  • Page 11: Storage System Dimensions

    The following diagrams show the dimensions of a controller enclosure. The dimension values do not include any protruding parts (approximation). Figure 1 Controller Enclosure Dimensions 482mm Side Front FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 12: Figure 2 Drive Enclosure Dimensions

    The diagrams below show the dimensions of a drive enclosure. The dimension values do not include any protruding parts (approximation). Figure 2 Drive Enclosure Dimensions Side 482mm Front FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 13: Compliance Standards

    WEEE-compliant (waste electrical and electronic equipment) Power conversion efficiency • ® 80PLUS GOLD *1: The target ETERNUS AF is the ETERNUS AF250 S2. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 14: Package Size

    *4: These values are for product ID ETFP4DU-L. *5: These values are for product ID ETFP16U-L / ETFP12U-L. *6: These values are for product ID ETFP48U-L / ETFP32U-L. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 15: Installation Area

    Secure service areas that are 850mm or more in the front and rear of the ETERNUS AF. Figure 3 Installation Area and Service Area Rear service area 850mm or more ETERNUS AF Front service area 850mm or more FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 16: Installation Environment

    Estimate the amount of heat in the exhaust air from the ETERNUS AF by using the heat generation amount and exhaust air amount that are listed in "Installation Specifications" (page FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 17: Installation Methods

    When using power distribution units, make sure that the current capacity totaling the current consumption val- ue of power cords that connect to the enclosures does not exceed the actual usage rating of the power distribu- tion unit. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 18: Specifications For Optional Power Supply Products

    NEMA L6-15P NEMA L6-15R 4.0m Rating: 250V 10A tween the ETERNUS AF (Normal usage rating: and the socket (IEC60320 C13 n NEMA L6-15P) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 19: Table 8 Specifications For Ac125V Power Cords (For Regions Other Than The Emeia, Central American, And Carib- Bean Regions)

    IEC60320 C13 0.5m Rating: 250V 10A tween the ETERNUS AF 1.0m (Normal usage rating: and the socket 1.5m (IEC60320 C13 n 3.0m IEC60320 C14) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 20: Figure 4 Power Distribution Units (Ac8A/200-240V, 1U, 4 Outlets, 2 Inlets)

    Socket type rating Plug type Cable length (Socket) (Socket) IEC60320 C13 NEMA L6-30P NEMA L6-30R 4.4m Rating: 250V 30A (Normal usage rating: 24A) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 21: Figure 6 Power Distribution Units (2U)

    Socket type rating Plug type Cable length (Socket) (Socket) IEC60320 C13 NEMA L6-30P NEMA L6-30R 4.0m Rating: 250V 30A (Normal usage rating: 24A) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 22: Figure 7 Power Distribution Units (2U)

    Socket type rating Plug type Cable length (Socket) (Socket) IEC60320 C13 NEMA L6-30P NEMA L6-30R 4.0m Rating: 250V 30A (Normal usage rating: 24A) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 23: Required Number Of Outlets/Sockets

    Power distribution unit (AC24A/200-240V, 2U, 16 out- lets) Power distribution unit (AC24A/200-240V, 1U, 4 outlets) ETERNUS AF (without power distribution units) AC 100 – 120V AC 200 – 240V FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 24: Figure 8 Breaking Characteristics Of Distribution Board Circuit Protectors

    0.04 0.02 0.01 1.5 2 5 6 7 8 10 15 20 30 40 50 80 100 Current (ratio for the current rating) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 25: Figure 9 Example Of A Power Supply Connection When A Power Distribution Unit (1U) Is Used

    Line 1 Line 0 Distribution Distribution board board ↓ To power supply facility ↓ To power supply facility PSU: Power Supply Unit Circuit Protector FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 26: Figure 10 Example Of A Power Supply Connection When A Power Distribution Unit (2U) Is Used

    Line 0 Line 1 Distribution Distribution board board ↓ To power supply facility ↓ To power supply facility PSU: Power Supply Unit Circuit Protector FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 27 Controller enclosure Power distribution unit Line 0 Line 1 Distribution Distribution board board p To power supply facility p To power supply facility FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 28: Input Power Supply Lines

    When selecting a single configuration, take into consideration the availability of the system. Figure 12 Dual-Line Power Supply (When Connecting to Power Sockets) Power distribution unit ETERNUS AF Line 1 Line 0 FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 29: Figure 13 Dual-Line Power Supply (When Connecting To A Ups Unit)

    Line 0 Figure 16 Single-Line Power Supply (When Connecting to a Power Socket and a UPS Unit) Power distribution unit ETERNUS AF Line 0 FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 30 Power distribution unit Power distribution unit ETERNUS AF Drive enclosure Controller enclosure Line 0 Line 1 FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 31: Rack Installation Specifications

    If drive enclosures are to be added in the future, securing sufficient space for power distribution units in the • bottom of the rack is recommended. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 32: Cable Connection

    The distance between the enclosure and the power distribution unit in this example is 6U, which is calculated by subtracting the PDU in location 1 from the DE in location 7. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED...
  • Page 33: Figure 18 Ac Cable Connection

    OUT1 to OUT4 and the current capacity totaling the current consumption value of power cords that connect to outlets OUT5 to OUT8 within 8A for each power distribution unit. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED...
  • Page 34: Table 19 Usage Of Cables For Connecting Enclosures

    Used as extension cables when the connection length between the racks is longer than 6.0m. Used as extension cables when the connection length between the racks is longer than 15.0m. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED...
  • Page 35: Installable Racks

    This section explains the racks in which the ETERNUS AF can be installed. Fujitsu Racks The ETERNUS AF can be installed in a Fujitsu 19-inch rack. For information about whether the ETERNUS AF can be installed in an EOLed rack or not, contact your sales representative.
  • Page 36: Figure 19 Unit Installation Area

    When determining service areas, refer to the manual of the rack that is to be used. Make sure to perform the installation according to the placement requirements described in "Installation Specifi- cations" (page 7) "Installation Environment" (page 16). FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Site Planning Guide Copyright 2021 FUJITSU LIMITED P3AG-1812-06ENZ0...
  • Page 37 However, Fujitsu shall assume no responsibility for any operational problems as the result of errors, omissions, or the use of information in this manual. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information •...