Download Print this page

Troubleshooting - Honeywell R6H911RF Applications Manual

2-zone application 2x t6r smart thermostat & 2-channel receiver box

Advertisement

TROUBLE SHOOTING
Symptom (Fault message)
The Receiver box button LED
is green but the zone valve
does not switch on.
One of the status LED's on
the Receiver box is red
(Communication loss)
Thermostat alert messages
WIFI RADIO ERROR
INTERNAL MEMORY ERROR
NO COMMUNICATION
RECEIVER BOX
RF SIGNAL OFRECEIVER
BOX LOW
NO RECEIVER BOX
NO INTERNET
NO WIFI SIGNAL
REGISTER ONLINE
WIFI NOT CONFIGURED
BOILER FAILURE FAULT xx
BOILER LOW WATER PRESSURE
ORDERING SPECIFICATION
Description
T6R Wireless Smart Thermostat (spare)
2-channel Receiver box R6 wireless
(spare)
Honeywell Control Systems Limited
Newhouse Industrial Estate
Motherwell ML1 5SB
United Kingdom
Possible Cause
Zone valve wiring might be incorrect
or broken
The Receiver box receives no
communication from that
thermostat: RF communication
might be too far or is blocked due to
Receiver box location.
Thermostat is no longer powered.
The Wi-Fi radio of thermostat is
faulty.
The internal memory of thermostat
is faulty.
The thermostat receives no
communication from the
thermostat: RF signal is blocked due
to the location of the thermostat.
Receiver box is no longer powered.
There is a weak radio signal from the
Receiver box
The thermostat is not bound with
the Receiver box
Thermostat has no longer Internet
connection.
Thermostat has no longer a Wi-Fi
connection.
Thermostat is connected to Internet
but not yet registered to an account.
Thermostat is not connected to
Wi-Fi network.
The OpenTherm boiler reported a
failure number XX.
The boiler reported low water
pressure.
Model
T6H700RW4011
R6H911RF4018
Remedy
Check the Receiver box wiring
Try to move thermostat or Receiver box closer or
re-locate.
Check the power to the thermostat
Power cycle the thermostat (30s no power) and
restart, else replace thermostat
Replace thermostat
RF communication might be too far or is blocked
due to the location of the Thermostat or Receiver
box.
Check the power to the Receiver box
Try to move thermostat or Receiver box closer or
re-locate.
Bind or re-bind the Receiver box
End user needs to check their Internet connection
via router.
End user needs to check their Wi-Fi network of
router.
End user needs to download the App, create an
account and register the thermostat.
End user needs to download the App, create an
account, connect and register the thermostat.
Check the boiler
Fill up the hydronic system with water.
EAN code
5025121381161
All packaging contains 6
languages: English, Dutch,
5025121381130
French, German, Italian and
Spanish
T6R-2Z-EN0H 8603 NL01 R0718
T6 SMART THERMOSTAT
Literature

Advertisement

loading

This manual is also suitable for:

T6h700rw