Idrx-Acc - Omega iDRX-ACC User Manual

Idrx signal conditioner series
Table of Contents

Advertisement

iDRX-ACC SPECIFICATIONS
10 mA, 100 mA, 1 Amp, 5 Amp AC current
INPUT RANGES:
Dedicated input terminals for (10, 100 mA same input), 1
Amp and 5 Amp. Return terminal common to all ranges.
30 Hz to 1KHz
FREQUENCY RANGE:
3.3 Ohms for 10, 100 mA input
INPUT IMPEDANCE:
0.2 Ohms for 1 Amp input
0.04 Ohms for 5 Amp input
Dielectric strength per 1 minute test based on
ISOLATION:
EN 61010 for 50 Vdc or Vrms working voltage.
Three way Isolation:
• Power to input 1800V Peak
• Power to analog output/communication 1800V Peak
• Input to analog output/communication 1400V Peak
10% Above full scale continuously
INPUT OVER-CURRENT PROTECTION:
100% Above full scale for 10 seconds
Dual slope
ANALOG TO DIGITAL TECHNIQUE:
3 readings/second
READ RATE:
± 0.2% of FS from 30 Hz to 1 KHz
ACCURACY AT 25 °C:
10, 100 mA Range 100 ppm/°C typical
TEMPERATURE STABILITY:
1 Amp Range 150 ppm/°C typical
5 Amp Range 200 ppm/°C typical
2 seconds to 99% of the final value
STEP RESPONSE FOR RS485 OUTPUT:
(Filter time constant = 64)
To verify the response time, check the carriage return
RESPONSE TIME:
<CR>, it will be sent at the end of the response. You can
send another command after you receive the <CR>.
i.e.
send: *01X01
response: 01X01<DATA><CR>
Note:
01 is address.
30 minutes
WARM UP TO RATED ACCURACY:
10 to 32 Vdc
INPUT POWER:
2.4 Watts (100 mA at 24 Vdc)
POWER CONSUMPTION:
-5 to +55 °C
OPERATING AMBIENT:
-40 to +85 °C
STORAGE TEMPERATURE:
90% at 40 °C non-condensing
RELATIVE HUMIDITY:
RETURN
{
Page 22
J 4
5A
1A
100mA
J 1
J 3
J 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idrx-acvIdrx-fpIdrx-tcIdrx-stIdrx-prIdrx-rtd