Commands For Accessing Eeprom - Omega iDRX-ACC User Manual

Idrx signal conditioner series
Table of Contents

Advertisement

IV.

COMMANDS FOR ACCESSING EEPROM:

NO.
command letter index
1.
R,W
2.
R,W
3.
R,W
4.
R,W
5.
R,W
6.
R,W
7.
R,W
8.
R,W
9.
R,W
10.
R,W
11.
R,W
12.
R,W
13.
R,W
14.
R,W
15.
R,W
16.
R,W
17.
R,W
NOTE:
1.
Data (Number of hex digits) = 2 * number of bytes
2.
command letter
R
W
3.
"W" commands should be followed by "Z01" command for new values to take
effect.
A.
COMMAND FORMAT (TRANSMITTING):
*[nn]Cxx[data][hh]<cr>
Note: Data is required if Command Letter is "W"
B.
RESPONSE FORMAT (RECEIVING):
A.
Correct response :
If unit is in echo mode* (see "BUS FORMAT") :
1.
*echo mode = unit will send back the command.
meaning
01
Input range or function
02
Input/output Configuration
03
Decimal point
04
Filter time constant
05
Reading Scale
06
Reading Offset
07
Communication parameters
08
Communication bus format
09
Communication Data format
0A
Communication device address1
0B
Communication recog. char.
0C
Unit of measure
0D
Gate time
0E
Debounce time
0F
Transmit time
12
Reading Scale (iDRX-PR)
13
Reading Offset (iDRX-PR)
Read from EEPROM
meaning
Write to EEPROM
[nn]Cxx[data][hh]<cr>
# of bytes
Page 6
1
1
1
1
3
3
1
1
1
1
3
1
1
2
3
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idrx-acvIdrx-fpIdrx-tcIdrx-stIdrx-prIdrx-rtd

Table of Contents