Description Of Data - Omega iDRX-ACC User Manual

Idrx signal conditioner series
Table of Contents

Advertisement

:
?ee
?43
?46
?48
?50
:
<cr>
If Baud rate, Recognition character or address are not correct then the UNIT will not
respond.
Note:
V.

DESCRIPTION OF DATA :

For the following Bit Pattern. The LSB is always bit 0. Bit numbers are always counted
from right to left, with the rightmost digit being bit 0, and the next to the left would be
bit 1.
1. INPUT RANGE:
This is one byte data (2 characters). This byte will specify input range and other input
configurations of each model. Bit pattern for different models :
Bits:3210
a. INPUT RANGE BYTE VALUE
Bit 6-4: not used
Bit 7:
Special code indicating an error has occurred as:
:
Command error
( occurs if command letters and indexes are invalid)
:
Format error
( occurs if length of the data or number of characters is not correct )
:
Checksum error
( occurs if checksum is not correct )
:
Parity error
( occurs if parity is not correct )
Carriage return
0000
0001
0010
0011
0100
0101
0110
0111
1000
(1001-1111 not used )
0
Line frequency = 60Hz
1
Line frequency = 50Hz
TC
J
400 mV ac
K
T
40 V ac
E
400 V ac
N
DIN J
R
S
B
Page 8
ACV
ACC
10 mA
4 V ac
100 mA
1 A
5 A
----
----
----
----
----
----
----
----
----
----

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idrx-acvIdrx-fpIdrx-tcIdrx-stIdrx-prIdrx-rtd

Table of Contents