iR ADV C255iF/ C355iF Advanced Maintenance Guide
Procedure
M1
Clean ADF for Dust
M2
Clean ADF Rollers
M3
Clean the Glass/ Optics
Detail & Action
1. Inside cover
2
1
Clean the rollers if they were not replaced in step
1. Separation Pad
2. P/U, Rollers
1. Copy Glass
2.
CIS Unit
1
2
Clean
Clean
Note
Point:
No.5.
Clean the rollers using lint free paper with water.
Check
Sensors should be cleaned by blower brush.
If the rollers are under 50% usage, cleaning
may not be necessary.
Clea
n
Chec
k
Clean
Point:
1. Clean the Copy Glass with Oil cleaner (FY9-
6020-000).
2. Check that there is no dirt or any foreign
particles on the scanner system part. (CIS/CCD)
3. Check that the CIS/CCD unit moves smoothly
and there is no dirt on the rail.
4. Check that there is no dew condensation found
on the scanning system parts.
Time
Clean
3
min
Clean
3
min
Clean
3
min