Service
Manual

Adjustment and checking of the outlet pressure

The gas outlet pressure of the solenoid
valve is adjusted at the factory. If you have
to make another adjustment, proceed as
follows.
A
Inlet
B
Outlet
D
Outlet pressure regulator
adjustment screw plug
E
Inlet pressure tapping
F
Outlet pressure tapping
T
Head regulation
1
Close the gas inlet and remove the
binding screw from the pressure
tapping (F) and connect the manometer
tube.
2
The electricity supply must be
energized otherwise gas will not be
supplied to the burner.
3
Open and check the gas inlet main
burner using the manometer on the
pressure tapping (F).
4
Remove pressure regulator cap (D).
5
Using a screwdriver, slowly turn the
adjustment screw until the required
pressure (P) is indicated on manometer
(see tables on the following pages).
Turn the adjustment screw clockwise
to increase and counter-clockwise to
decrease gas pressure.
Reset the pressure regulator cap, close off the gas inlet, remove the manometer tube and
6
put the binding screw back in (F).
04102011/GB
51.2010
IMPORTANT
Adjustments should be made by qualifi ed personnel only.
Installation
P
F
10
D0290
D0034
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic4 4825 ffsIc4 4832 ffs