Replacement Of The Fc510 Switch; Replacement Of The Km12 Contactor; Replacement Of The Air Pilot Valve And The Pneumatic Block; Compressed Air System - Electrolux IC4 4819 FFS Service Manual

Feeder ironer folder & stacker
Table of Contents

Advertisement

Service
Manual
Before any intervention it is essential to cut off all supply of the machine
Repair

Replacement of the FC510 switch:

Remove / Assembly:
1. Remove the left side frame of the machine.
2. Disconnect the wire of the faulty switch.
3. To make a reference mark on the casing in order to facilitate the adjustment of the switch.
4. Remove the switch and to replace it by new.
5. Adjust the new switch according to the reference mark makes previously.
6. Connect the wire on the new switch.
7. Put back the frame.

Replacement of the KM12 contactor:

If the contact of the contactor do not stick when the contact coil is supplied manually, this means
that the contactor is faulty.
Remove / Assembly:
1. Remove the left side frame of the machine.
2. Disconnect the wire of the faulty contactor.
3. Remove the contactor and replace it by a new one.
4. Connect the wire on the new contactor.
5. Put back the frame.

Replacement of the air pilot valve and the pneumatic block:

see chapter «Compressed air system»
04102011/GB
06.2009
Cross folding
(electricity, steam, water, gas, compressed air...).
33