Password Setting - Hitachi P1-00080-L Basic Manual

Sj series
Hide thumbs Also See for P1-00080-L:
Table of Contents

Advertisement

Chapter 4
[UA-01]~[UA-19]
■Parameter mode (U code)

Password setting

Code/Name
UA-01
Display password
UA-02
Software-Lock password
・When using the password, display and parameter mode
settings are locked
・Any other password than 0000 can be set. The password
can be cancelled by entering the set password. If you
forget your password, please note that the restrictions
will no longer be lift.
Display mode of keypad
Code/Name
00(Full display)/
01(Function-specific display)/
UA-10
Display
02(User setting)/
selection
03(Data comparison display)/
04(Monitor only)
UA-11
Option
00(Hidden)/01(Display)
parameter display
・Limit the displayed contents of the keypad.
・For more information, refer to the User's guide.
Accumulated power display adjustment/clear
Code/Name
UA-12
Clearance of accumulated
output power
UA-13
Accumulated output
power display gain
UA-14
Clearance of accumulated
input power
UA-15
Accumulated input power
display gain
・If [KHC] terminal is ON, the accumulated input power
can be clear.
・If [OKHC] terminal is ON, the accumulated output power
can be clear.
Software lock operation settings
Code/Name
UA-16
Software-Lock
selection
UA-17
Software-Lock
target selection
・Sets the software lock operation.
Keypad copy function restriction
Code/Name
UA-18
Data RW selection
・Restricts the copy function(Read/Write).
Keypad low battery warning
Code/Name
UA-19
Low battery warning
・Sets operation for when keypad is low on battery.
Range (unit)
Initial value
0000
0000~FFFF
0000~FFFF
0000
Range (unit)
Initial value
00
00
Range (unit)
Initial value
00(Disable)/
00
01(Clear)
1~1000
1
00(Disable)/
00
01(Clear)
1~1000
1
Range (unit)
Initial value
00([SFT] terminal)/
00
01(Always enable)
00(All data)/
00
01(All, except speed )
Range (unit)
Initial value
00(Not able to R/W)
00
01(Able to R/W)
Initial
Range (unit)
value
01(Warning)/02(Error)
For parameter configuration
Keypad communication lost operation
Code/Name
UA-20
Operation
selection when keypad
communication is lost
User-parameter setting function
Code/Name
UA-30
User-parameter automatic
setting selection
UA-31
User-parameter 1
UA-32
User-parameter 2
UA-33
User-parameter 3
UA-34
User-parameter 4
UA-35
User-parameter 5
UA-36
User-parameter 6
UA-37
User-parameter 7
UA-38
User-parameter 8
UA-39
User-parameter 9
UA-40
User-parameter 10
UA-41
User-parameter 11
UA-42
User-parameter 12
UA-43
User-parameter 13
UA-44
User-parameter 14
UA-45
User-parameter 15
UA-46
User-parameter 16
UA-47
User-parameter 17
UA-48
User-parameter 18
UA-49
User-parameter 19
UA-50
User-parameter 20
UA-51
User-parameter 21
UA-52
User-parameter 22
UA-53
User-parameter 23
UA-54
User-parameter 24
UA-55
User-parameter 25
UA-56
User-parameter 26
UA-57
User-parameter 27
UA-58
User-parameter 28
UA-59
User-parameter 29
UA-60
User-parameter 30
UA-61
User-parameter 31
UA-62
User-parameter 32
・Sets the data displayed when [UA-10]=02.
01
4-59
[UA-20]~[UA-62]
Range (unit)
00(Error)/
01(Error after deceleration stop)/
02(Ignore)/
03(Free-run)/
04(Deceleration stop)
Range (unit)
00(Disable)/
01(Enable)
no/
(parameter)
Initial
value
02
Initial
value
00
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents