Table 3-21     Problems resolved in versions prior to XCP 2050 (continue d)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
121206-001
RTIF2-
x
121219-002
RTIF2-
x
x
x
121219-004
RTIF2-
x
x
x
121219-005
RTIF2-
x
x
x
121219-006
RTIF2-
x
x
x
121219-009
RTIF2-
x
121219-010
Description
When starting the domain, the following
error message may appear.
Msg: PCI Express link not active
Some chassis may not be recognized if all
power cables are not connected within
four minutes when connecting the power
cables of the system that is composed of
multiple SPARC M10-4S chassis.
While powering on/off the power supply
interlocking group, the
showremotepwrmgmt(8) command may
be abnormally terminated with the
following message.
Controller response timeout.
When a component with high temperature
or low temperature at an air inlet is
registered, the information on the second
faulty component (the second suspect
component) displayed in the FRU may
not be correct.
Replacement of the power supply unit
(PSU) using the replacefru(8) command
may fail with "Warning:005".
If an error log indicating a fan failure,
"Power-on failure" or "Power-off failure",
is registered, other than the correct
component may be displayed as the
faulty FRU.
Error log "XSCF hang-up is detected"
may be registered when the switchscf(8)
command is executed.
Workaround
Ignore this message if the showhardconf
(8) command recognizes the PCI Express
(PCIe) card.
Make sure not to exceed four minutes to
finish connecting all the power cables
when the system is composed of multiple
SPARC M10-4S chassis.
Remove and connect the power cables of
all the chassis again when there is a
SPARC M10-4S chassis that is not
recognized.
Execute the showremotepwrmgmt(8)
command again.
Ignore the information on the displayed
second faulty component (the second
suspect component).
Execute the replacefru(8) command again
and replace the PSU.
If the failure is "Power-on failure" or
"Power-off failure", and the faulty
component is a fan, replace the following
component.
- For the SPARC M10-1
Motherboard unit (MBU)
- For the SPARC M10-4/M10-4S
PSU backplane unit
Ignore this error log.
Chapter 3 Information on Software
149