Fujitsu M10 Product Notes page 158

Hide thumbs Also See for M10:
Table of Contents

Advertisement

(Current)     :config1
(Next)           :config1
--------------------------------------------------------------
Index               :1
config_name   :factory-default
domains           :1
date_created:-
--------------------------------------------------------------
Index               :2
config_name   :config1
domains           :2
date_created:'20xx-yy-zz   hh:mm:ss'
2.
Set a dummy variable and then clear it for all logical domains.
Execute the following commands for all logical domains.
primary#   ldm set-variable fix-php=true  ldom
primary#   ldm remove-variable fix-php  ldom
3.
Save the changed configuration in XSCF to replace the current configuration
information.
In this example, the name of the current configuration information is replaced
with config1.
primary#   ldm remove-spconfig config1
primary#   ldm add-spconfig config1
4.
Restart all logical domains.
Restoration after erroneous detection of the "SCF Diagnosis
initialize RTC" error (RTIF2-131107-002)
[How to restore]
If phenomenon 1 occurs:
a. If the Oracle Solaris time has returned to January 1, 1970, execute the setdate(8)
b. If the Oracle Solaris time is other than January 1, 1970, contact a field engineer.
c. If the PPAR power is off, power on the PPAR. After that, check the Oracle
If phenomenon 2 occurs:
a. If the Oracle Solaris time has returned to January 1, 1970, it is necessary to
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
144
command to set the XSCF time again. In this case, the XSCF is reset. After that,
power off and on the PPAR.
In this case, do not execute the resetdateoffset(8) of setdate(8) command on the
XSCF.
Solaris time, and perform the above steps a. or b.
initialize the time difference between the XSCF time and Hypervisor on all of