Page 3
Preface Fujitsu would like to thank you for purchasing the FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 (here- inafter referred to as ETERNUS AF). The ETERNUS AF is designed to be connected to Fujitsu servers (Fujitsu SPARC Servers, PRIMEQUEST, or PRI- MERGY) or non-Fujitsu servers.
Page 4
Windows Server 2008 R2 for Itanium-Based Systems ® ® Microsoft Windows Server 2008 HPC Edition ® ® Microsoft Windows Server 2008 R2 HPC Edition FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 5
■ Abbreviations Used in This Manual • "ETERNUS AF250 S2" refers to the FUJITSU Storage ETERNUS AF250 S2 and "ETERNUS AF250" refers to the FUJITSU Storage ETERNUS AF250. • "ETERNUS AF" refers to the ETERNUS AF250 S2 and the ETERNUS AF250.
Page 6
The black "Must Do..." circle indicates actions that must be taken. The required ac- tion is both illustrated inside the black disk and written above it (e.g. Unplug). FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 7
- Be careful that no liquid seeps into the ETERNUS storage system when using cleaners, etc. - Do not use alcohol or other solvents to clean the ETERNUS storage system. Warning layout ribbon FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 8
Manufacturer’s label The model name and the serial number are listed. Device ID label The model name and the serial number are listed. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 9
Drive Enclosures Power Distribution Units (for Regions other than the EMEIA, Central American, and Car- ibbean Regions) Power distribution unit (AC200-240V, 1U) • FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 10
Preface Power distribution unit (AC200-240V, 2U) • FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 16
Operation Volume Creation ........................77 Table 7.1 ETERNUS AF Operation according to the Settings of the Auto Power Function and the Power Resume Function ..............................105 FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
This section provides the names of the components in the front of a controller enclosure. Figure 1.1 Front View of a Controller Enclosure Operation panel Drive Flange cover FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Drives and an operation panel are installed in the front of the drive enclosure. I/O modules and power supply units are installed in the rear. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Power Distribution Unit (AC200-240V, 2U, 12 Outlets) There are 12 outlets. Figure 1.6 Power Distribution Unit (AC200-240V, 2U, 12 Outlets) Main line switch Outlet (OUTPUT) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Power Distribution Unit (AC200-240V, 2U, 16 Outlets) There are 16 outlets. Figure 1.7 Power Distribution Unit (AC200-240V, 2U, 16 Outlets) Main line switch Outlet (OUTPUT) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Contact your sales representative or maintenance engineer if drives that are instal- led by default need to be uninstalled or moved to another slot. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
This section describes how to install the power distribution unit in a rack. Do Not Do not connect any devices other than the ETERNUS AF to the power distribution • unit. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
3rd hole (M6 screw) (M6 screw) Power distribution unit 1st hole 1st hole (M6 screw) (M6 screw) Power distribution unit base line Bracket FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 25
The blank panel should be attached at the same height as the power distribution unit. Blank panel (Rack pillar: front) Power distribution unit (Rack pillar: rear) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Attachment procedure Clip the M5 cage nut tabs into the desired hole from the inside. Side view M5 cage nut Rack pillar (square hole) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 27
The blank panel should be attached at the same height as the power distribution unit. Blank panel Power distribution unit (Rack pillar: front) (Rack pillar: rear) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Use the two plates to fasten the rack rails to the front rack pillars. Use the washers to fasten the rack rails to the rear rack pillars. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 29
(M5 screw) (M5 screw) Controller enclosure base line Rack rail Tighten the M4 screws of the rack rails that were slightly unscrewed in Step FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 30
Fasten the controller enclosure in the rack. Use three M5 screws to fasten it in the rack pillar. M5 screw M5 screws Attach the flange cover. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Use the two plates to fasten the rack rails to the front rack pillars. Use the washers to fasten the rack rails to the rear rack pillars. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 32
Failure to do so may cause injury. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 33
Fasten the drive enclosure in the rack. Use four M5 screws to fasten it in the rack pillar. M5 screws M5 screws Attach the flange cover. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Multipath iSCSI SAN Remote support center LAN for Operation Management SNMP manager PC for Operation Management/ PC for setup Mail server Syslog server FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
ETERNUS AF. If the server is connected, shut down the server, re- move the cable, and then restart the server. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
To change the installation directory, click the [Browse] button and select the installation directory. To leave the settings unchanged, click the [Next] button. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
In [Administrative Tools], click [iSCSI Initiator]. For the first startup, the following dialog appears. If there is no problem with service startup settings, click the [Yes] button. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 38
Chapter 3 Checking the Configuration Environment Server Connection Preparation On the [iSCSI Initiator Properties] screen, click the [Configuration] tab. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 39
To use the default initiator name, also click the [Change] button. This allows you to continue to use this initiator name even after changing the "server name". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
IP address: 192.168.1.2 Subnet mask: 255.255.255.0 Check the settings of the Web browser. For details on the required settings, refer to "Configuration Guide (Web GUI)". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Enter the IP address for the RMT port of the ETERNUS AF. The RMT port is a LAN port that is used during initial setup and to connect to the remote support center. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 43
The default LAN operation mode is "Auto Negotiation" which allows the ETERNUS AF to automatically recog- nize 1000BASE-T/100BASE-TX/10BASE-T and Full/Half-Duplex connections. However, some devices may re- quire that a fixed communication mode be set. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
When connecting the cables, position them so that they will not obstruct replacement of the power sup- • ply unit or controllers by the maintenance engineer. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 45
This section uses an iSCSI 10Gbit/s host interface (CA) as an example to show the connection procedure. Install an SFP+ module in the host interface port. This procedure is required only when an SFP+ module must be installed. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
0.75m mini SAS HD cables between enclosures are provided with drive enclosures. The following procedure explains how to connect the mini SAS HD cable between enclosures. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 48
The connectors on the cable with the "l" symbol are connected to the DI (IN) ports on the drive en- • closure. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
ETERNUS AF, and required settings. Power Cord Connection Connect the power cords to the ETERNUS AF. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Connecting two power cords for each enclosure to different two power supply facilities improves the availability of the power supply facilities against failures. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Remove the power cord clamp from the power distribution unit. Power cord clamp Power distribution unit FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
This section explains how to install a 12 outlet type power distribution unit as an example. This installa- tion method can also be applied to a 16 outlet type power distribution unit. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 53
: Connect OUTn of the power distribution unit #0 to the PSU#0 inlet of the ETERNUS storage system. : Connect OUTn of the power distribution unit #1 to the PSU#1 inlet of the ETERNUS storage system. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 54
#0 side and the power distribution unit #1 side to different power sources. AC input cables Power distribution unit#1 Power distribution unit#0 Connect to power outlets. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Perform the basic settings to use the Advanced Copy function. For details on these settings and performing SnapOPC+, refer to "Chapter 9 Advanced Copy Settings" (page 141). FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
M : 7th generation Sunday data ETERNUS AF SnapOPC+ By mounting the copy destination volumes, the past data is recognized as drives by the server FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
*1: SDV is used as the copy destination for SnapOPC+ and stores generation data. *2: SDPV is the expansion area of the SDV and is used to configure the Snap Data Pool (SDP) area. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
ETERNUS AF is set using the PC terminal for the initial setup of the ETERNUS AF. Figure 5.3 PC Terminal Connection for Initial Setup PC terminal LAN port LAN cable RMT port of Controller 0 (CM#0) Controller enclosure FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
● For 2U Figure 5.5 ON Position (Marked "|") of the Main Line Switches on a 2U Power Distribution Unit Main line switch FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
For the drive enclosure, the POWER LED on the power supply unit emits green lights and the fan revolves at • high speed for 30 seconds. Drive enclosure Controller enclosure Power supply unit (PSU#0) Power supply unit (PSU#1) POWER FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
IP address for the ETERNUS AF) ping 192.168.1.1 If the execution results in an error, check the network settings of the PC terminal. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
To change the language, click the [Option] button and select [English] or [Japanese] in [Language:]. Enter the User ID and Password. User ID: root Password: root (by default) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 63
Chapter 5 General Settings ETERNUS Web GUI Startup After logging in, the Initial Setup screen of ETERNUS Web GUI appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
The information that is set here is used for network management by SNMP. The name of the ETER- NUS AF is displayed in the login and operation screens of ETERNUS Web GUI. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 65
Set the required items and click the [Next >>] button. A confirmation screen appears. Click the [OK] button. The password is changed and the change completion screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 66
Click the [OK] button. The Thin Provisioning is set and the change completion screen appears. Click the [Done] button. The [Register Advanced Copy License] screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 67
A message to confirm whether to register the SED authentication key is displayed. Click the [Next >>] button. A confirmation screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 68
If the ETERNUS AF is accessed from a system with the same network address (or same subnet- work), the IP address does not need to be set. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 69
The [Logout] screen appears. Logout Click the [Close] button. Initial setup 1 is complete and the screen returns to the [Login] screen. Close the Web browser. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
When connecting the LAN cables, position them so that they will not obstruct • replacement of the power supply unit or controllers by the maintenance engi- neer. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 71
Connect the LAN cables of the MNT port to the network of the customer. If the RMT port is used for remote support, connect the LAN cable of the RMT port to the network for remote support. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Click the [System] tab on the navigation of the ETERNUS Web GUI screen. In [Category], click [Network]. The [Network] screen appears. Select the port to be set. In [Action], click [Setup Firewall]. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 73
The firewall settings are applied. Check the setting completion message and click the [Done] button. The screen display returns to the [Network] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
*1: Enter the capacity of the copy source volume during creation of SDV. *2: If "7" is specified for the number of volumes, sdv0, sdv1, sdv2, sdv3, sdv4, sdv5, and sdv6 volumes are created. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Figure 5.10 Copy Data Destination Volume (SDPV) Creation Backup RAID group (RG1) Copy data destination volume 3.84TB 3.84TB 500GB 3.84TB 3.84TB 3.84TB sdpv (Snap Data Pool Volume) RAID5 (4+1) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 81
Click the [OK] button. The volume is created and the registration completion screen appears. Click the [Done] button. The screen display returns to the [Volume] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Click the [Component] tab on the navigation of the ETERNUS Web GUI screen. On the [Component] screen, click [Drives] in [Category]. The [Drives] screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 83
Select the drive that is to be registered as the Dedicated Hot Spare and click [Assign Dedicated HS] in [Action]. The [Assign Dedicated Hot Spare] screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 84
The Dedicated Hot Spare is registered and the registration completion screen appears. Click the [Done] button. The screen display returns to the [Drives] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
In the [Setting based on Severity] tab screen, select the required items. On the screens that are displayed by clicking each level tab, select the required items. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
IP address and the Allowable IP address (IP address of the monitoring server or the network address to which the monitoring server belongs) on the [Setup Network Environment] screen of ETERNUS Web GUI. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 87
Select [Enable] for [SNMP Function], set the required items, and click the [Set] button. Select the LAN port that was set up in Step 1 for "LAN Port used for SNMP". A confirmation screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 88
The SNMP Manager settings are applied. Check the setting completion message and click the [Done] button. The screen display returns to the [Network] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 89
The SNMP community settings are applied. Check the setting completion message and click the [Done] button. The screen display returns to the [Network] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 90
In [Action], click [Setup SNMP Trap]. The [Setup SNMP Agent Trap] screen appears. In the trap list of the [Setup SNMP Agent Trap] screen, click the [Add] button. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 91
Download the MIB file that is registered in the ETERNUS AF. In [Action], click [Download MIB File]. The [Download MIB File] screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 92
The MIB file is saved. Check the setting completion message and click the [Done] button. The screen display returns to the [Network] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Enter the destination e-mail address or addresses for the Destination E-Mail Address fields. Click the [E-Mail Server Settings] tab. The [E-Mail Server Settings] tab screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 94
Click the [Set] button to apply the specified settings. A confirmation screen appears. Click the [OK] button. The e-mail notification settings are applied. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
To send messages in RFC5424 format to a target Syslog server that supports RFC5424, select "on(RFC5424)". If this is not the case, select "on(RFC3164)". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
REMCS is not specified or is stopped. When REMCS is used, suspend the REMCS function, and then ena- ble the AIS Connect function. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
(Country Code : Country Name)". Perform the other additional settings that are required. Click the [Set] button. A confirmation screen appears. Click the [OK] button. The AIS Connect settings are applied. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
The [Support Information] tab screen of the [Remote Support] screen appears. In [Action], click [Setup Remote Support]. The [Setup Remote Support] screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 99
The connection check result is sent to the e-mail address that is set in "Result notification information". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
To send messages in RFC5424 format to a target Syslog server that supports RFC5424, select "on (RFC5424)". If this is not the case, select "on (RFC3164)". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Register the file that was downloaded in "Download the MIB file" (Step 6) in "6.2.1 SNMP Trap Setup" (page 86) as the MIB definition file for the monitoring software. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
In the [Send SNMP Trap Test] screen, click the [Send] button. A confirmation screen appears. Click the [OK] button. The test transmission of the SNMP Trap is performed. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
The [System] screen appears. In [Category], click [Network]. The [Network] screen appears. In [Action], click [Setup E-Mail Notification]. The [Setup E-Mail Notification] screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 104
Check that the test e-mail is sent to the e-mail addresses that are set. For details on the event code and message of the test e-mail, refer to "Message List". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
The ETERNUS AF is automatically turned on when AC power is supplied and when power is restored after a power failure. Power Resume function is enabled FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 106
The Auto Power function and/or the Power Resume function setting is applied. Check the setting completion message and click the [Done] button. The screen display returns to the [System Settings] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
To control power supply with servers in a network to which the ETERNUS AF does not belong, set • "Gateway" and specify the server IP address or the network address in "Allowable IP Address". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 108
The network environment settings are applied. Check the setting completion message and click the [Done] button. The screen display returns to the [System Settings] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Click the [Connectivity] tab on the navigation of the ETERNUS Web GUI screen. On the [Connectivity] screen, click [Host Response] in [Category]. In [Action], click [Add Host Response]. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
For the settings for connection using other interfaces, refer to "Configuration Guide (Web GUI)". Also refer to "Configuration Guide -Server Connection-" as required. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 111
The iSCSI host group is added and the registration completion screen appears. Click the [Done] button. The screen display returns to the [Host Group] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 112
CHAP Specify [ON] to use unidirectional CHAP authentication or bidirectional CHAP authentication for the target port and [OFF] to use neither of them. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 113
The port parameter is set and the setting completion screen appears. Click the [Done] button. The screen display returns to the [iSCSI Port] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 114
The CA port group is created and the setting completion screen appears. Click the [Done] button. The screen display returns to the [CA Port Group] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 115
Enter the number for the first LUN and number of LUNs to allocate to the LUN group in [LUN Setting], select the number for the first volume to be allocated, and click the [OK] button. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 116
Select the "Host Group", the "CA Port Group", and the "LUN Group" that are to be associated. Click the [Browse] button in [Host Group]. A screen to select the host group appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 117
[Create] button. A confirmation screen appears. Click the [OK] button. The host affinity is created and the registration completion screen appears. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Set the CA reset group member ports and click the [Modify] button. In the confirmation screen, click the [OK] button. Click the [Done] button to return to the [CA Reset Group] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
After confirming that the ETERNUS AF is in READY status, turn on the server. On the [iSCSI Initiator Properties] screen, click the [Discovery] tab. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 120
When setting access restrictions, the settings related to CHAP authentication is required. For details on CHAP authentication, refer to "Configuration Guide -Server Connection-". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 121
To enable mutual authentication, select [Perform mutual authentication]. Click the [OK] button. The screen display returns to the [Discover Target Portal] screen. Click the [OK] button. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 122
On the [iSCSI Initiator Properties] screen, click the [Discovery] tab. Confirm that the specified settings are correctly reflected to [The system will look for Targets on follow- ing portals]. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 123
On the [iSCSI Initiator Properties] screen, click the [Targets] tab. Confirm whether the specified contents in [The system will look for Targets on following portals] have been applied correctly before checking connection. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 124
On the [Advanced Settings] screen, specify the following items under [Connect using] and click the [OK] button. Local adapter: Microsoft iSCSI Initiator Initiator IP: IP address of the server (A in Figure 8.1) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 125
Target portal IP: IP address of the ETERNUS AF (C in Figure 8.1) Confirm that the [Add this connection to the list of Favorite Targets.] checkbox is selected and click the [OK] button. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 126
Initiator IP: IP address of the server (B in Figure 8.1) Target portal IP: IP address of the ETERNUS AF (D in Figure 8.1) FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 127
Chapter 8 SAN Connection Settings Server Connection Setup Confirm that [Status] of the two targets has changed to [Connected] and click the [OK] button. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
The following procedure explains how to check LUN using the Windows Device Manager. Open [Device Manager] and expand [Disk drives]. Confirm that the same number of "FUJITSU..." items are displayed as the number of LUNs that are set. If the example is used, eight "FUJITSU..." items are displayed.
Select the checkbox for eight disks in this example. When Windows Server 2008 Enterprise is used, [Initialize Disk] does not appear. Perform the steps from Step 3 onwards. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 131
The LUNs that are set with the ETERNUS AF are recognized as [Offline]. Right-click all the disks displayed as offline, and select [Online]. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 132
SAN Connection Settings Server Connection Setup [Offline] changes to [Not Initialized]. Right-click all the disks to be changed to online, and select [Initialize Disk]. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 133
When the [Initialize Disk] screen appears, confirm that all the disks are selected and click the [OK] but- ton. Confirm that the initialized disks are displayed as [Online]. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 134
The following procedure explains how to set up the operation disk. Select [Disk Management] from [Computer Management]. On the [New Simple Volume Wizard] screen, click the [Next] button. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 135
Perform the settings as shown below. File system Drive that is to be Volume No. Volume name Type Capacity created NTFS main Standard FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 136
[Format Partition] appears. Click the [Next] button. [Completing the New Simple Volume Wizard] appears. Click the [Finish] button. Check that the specified settings are displayed correctly. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 137
Set up the disk created in [Snap Data Volume]. During volume creation, right-click the disk created in [Snap Data Volume] and select [New Simple Vol- ume]. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 138
Without changing the default settings of [Specify Volume Size], click the [Next] button. Assign a drive letter in [Assign Drive Letter or Path] and click the [Next] button. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 139
*1: The capacity that is displayed in "( )" is the copy source capacity. Select [Do not format this volume], and click the [Next] button. [Completing the New Simple Volume Wizard] appears. Click the [Finish] button. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 140
Step 7 for all the disks created in [Snap Data Volume]. In this case, seven disks are created as [Drive Letter: Assigned, RAW]. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
In [Action] on the [Setting] screen, click [Modify Copy Parameters]. Set the required items and click the [Modify] button. In the confirmation screen, click the [OK] button. Copy table size setting starts. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
On the navigation of the ETERNUS Web GUI screen, click the [Advanced Copy] tab. In [Action], click [Start SnapOPC+]. Click the [Browse] button of the copy source volume. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 147
Select the "No.: 0, Name: main" volume. In the same way as the copy source volume, click the [Browse] button of the copy destination volume. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 148
In the confirmation screen, click the [OK] button. The SnapOPC+ session starts. Click the [Done] button to return to the [Advanced Copy] screen. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 149
In this case, the copy source volume number is "0" and the copy destination volume numbers are from "1" through to "7". Open [Disk Management] from [Computer Management]. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 150
Check if the file that was created in Step 8 "■ Operation Disk Settings" (page 134) "8.2.3.2 Disk Settings" (page 134) is displayed for the copy source drive. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 151
Old data can be restored by simply copying and pasting the data files that are to be restored from the server. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
NUS AF. Check the status of each component on the [Storage] screen. If there is a component in Warning or Error status, contact your sales representative or maintenance engi- neer. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
GUI screen. In the [RAID Group (Basic Information)] screen that appears, select which RAID group to check the information for and click the No. or name of this RAID group. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
In the [Volume (Basic Information)] screen that appears, select which volume to check the informa- tion for and click the No. or name of this volume. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Click the [Start] button for Windows, expand [ETERNUS Multipath Driver] from [All Programs], and open [ETERNUS Multipath Manager]. Check that the LUN status is normal (that the signal icon is blue). FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
This section explains how to use the Power switch and the power synchronization unit to turn off the ETER- NUS AF. For other procedures, refer to the related manuals. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 157
) of the drive enclosures are turned off. ■ When a Power Synchronized Unit Is Used If the server is turned off, the ETERNUS AF is also turned off. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Operations are performed from the business server as an ETERNUS SF AdvancedCopy Manager agent and from the operation management server as an ETERNUS SF AdvancedCopy Manager manager. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 159
Register the replication source volumes and the replication destination volumes. For more details on the settings for ETERNUS SF AdvancedCopy Manager, refer to "ETERNUS SF AdvancedCopy Manager Operation Guide". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
To use Storage Cluster, the ETERNUS SF Storage Cruiser Storage Cluster option is necessary. A Storage Cluster controller is required to perform automatic failover. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 161
Storage Cluster controller settings (when performing automatic failover) • For more details on the settings for ETERNUS SF Storage Cruiser, refer to "ETERNUS SF Storage Cruiser Opera- tion Guide". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Improved and stabilized Storage Cruiser responses for prioritized operations Volumes for Server A Volumes for Server C Volumes for Server B ETERNUS AF FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 163
Specify the target performance value for each volume in the operation management server (ETERNUS SF Storage Cruiser). For more details on the settings for ETERNUS SF Storage Cruiser, refer to "ETERNUS SF Storage Cruiser Opera- tion Guide". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
ETERNUS VASA Provider • Status check of the ETERNUS AF ETERNUS SF • Profile-Driven Storage Storage Cruiser • Storage DRS ETERNUS AF FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
Page 166
For more details on the settings for ETERNUS SF Storage Cruiser, refer to "ETERNUS SF Web Console Manual" and "ETERNUS SF Storage Cruiser Operation Guide". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Create ODX volumes after enabling the ODX settings for the Advanced Copy function in the ETERNUS AF with ETERNUS Web GUI. For details on the SCVMM2012 settings, refer to the manual of the SCVMM2012. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AG-1832-04ENZ0...
A Syslog server is required for the destination for the transmission of the audit log that is collected. Note that ETERNUS SF KM is required when linking with the key management server. FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 169
ETERNUS SF KM. The certificate for ETERNUS SF KM must also be registered in the ETERNUS AF. For details on the setting procedures and setting items, refer to "ETERNUS SF KM Installation Guide". FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic) Copyright 2017 FUJITSU LIMITED...
Page 170
However, Fujitsu shall assume no responsibility for any operational problems as the result of errors, omissions, or the use of information in this manual. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information •...