  • Page 1: User Manual

    5-inch High Speed Dome User Manual V2.2.0 Hikvision Digital Technology Co., Ltd. http://www.hikvision.com...
  • Page 2 The updates will be added into the new version of this manual. We will readily improve or update the products or procedures described in the manual. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 3: Safety Instruction

    5. Do not aim the camera at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of CCD at the same time. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 4 7. Please use a soft and dry cloth when clean inside and outside surfaces of the dome cover, do not use alkaline detergents. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 5: Table Of Contents

    Rebooting the Dome ..............................32 Appendix ......................................... 33 Appendix 1 Lightning & Surge Protection ............................. 33 Appendix 2 RS485 Bus Connection ..............................34 Appendix 3 24VAC W ire Gauge & Transmission Distance......................36 © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 6 5-i nch High Speed Dome User Ma nual Appendix 4 Table of Wire Gauge Standards ..........................37 Glossary ........................................38 © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 7: Table Of Contents

    White Balance: White balance is the white rendition function of the speed dome to adjust the color temperature according to the environment automatically. It can remove the unrealistic color casts in © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 8 Cable is connected and data can be normally received, but the settings of address and command are incorrect. Cable is connected, but the received data does not comply with the requirements of Manchester code. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 9: Chapter 2 Getting Started

    The version of the firmware. VERSION The date when the program of the software is compiled. BUILD DATE 2.2 System-defined Presets Purpose: © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 10 System-defined Presets of Manchester Code Control Protocol Table 2-3 Preset Preset Function Function Remote reboot Auto-flip Access main menu Pattern 1 Stop programming pattern Pattern 2 Pattern 3 © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 11: Chapter 3 Menu Operation

    2. Click the up/down or left/right buttons in the PTZ control panel to choose the value from the selectable list. 3. Press IRIS+ to confirm the change or click IRIS- to cancel and restore the original value. The diamond mark will change back to be stuffed. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 12: Checking And Configuring System Parameters

    You can check and also edit the system information of the software address, baudrate, system time, etc. on the system information settings menu. Enter the system information settings menu: MAIN MENU > DOME SETTINGS > SYS INFO SETTINGS © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 13 After you enable/disable the soft baudrate, the speed dome will reboot automatically to activate the settings.  Protocol and RS-485 settings Purpose: This speed dome allows you to configure the protocol via OSD menu. Steps: © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 14 5-i nch High Speed Dome User Ma nual 1. Select the protocol. Choose the protocol on PROTOCOL SET submenu. You can configure it as AUTO MATCH, PELCO-P, PELCO-D, HIKVISION, KALATEL or VICON. When you choose AUTO MATCH, it is protocol self-adaptive. 2. Set the protocol status.
  • Page 15: Configuring Image Parameters

    (2) Click up/down direction buttons to choose the focus mode as AF, MF or HAF. AF (Auto-focus): The lens remains in focus during PTZ movements. It is the default focus mode. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 16 You can set it as 1, 2, 4, 8, 15, 30, 50, 125, 180, 250, 500, 1000, 2000, 4000 or 10000. Note: The value of X indicates that the shutter speed is 1/X second. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 17: Configuring The Display Parameters

    Sharpness: The sharpness function can increase the auto-gain of the speed dome and sharpen the edges in the picture to enhance the picture details. You can set the SHARPNESS level from 0 to 15. The default setting level is 8. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 18: Image Flip

    You can set the HLC function level as 0-3.  Image flip: If you turn the IMAGE FLIP function on, the image will be flipped diagonally along its central axis, shown as the mirror reflection of the image. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 19: Configuring Privacy Mask

    (1) Move the cursor to SET BLANK and click IRIS+ button to enter edit mode. You will see a purple privacy mask on the live window. ADJUST BLANK POS FOCUS SHIFT STATUS SAVE: OPEN QUIT: CLOSE Set the Privacy Mask Figure 3-7 © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 20: Configuring Osd Settings

    4. Click the left/right direction buttons to position the cursor to the characters of the title. 5. Get the codes for a specific character and enter each code (number) by calling the preset © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 21 You can enable or disable the on-screen display of PTZ movements, alarms, time, presets, etc., and configure the display time. Steps: 1. Enter the display settings menu: MAIN MENU > DOME SETTINGS > SYS INFO SETTINGS > DISPLAY SETTINGS © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 22: Configuring Ptz Control Parameters

    You can configure pan, tilt and zoom movements, and configure PTZ control functions including presets, patrols, patrols, etc. for the high speed dome. 3.4.1 Configuring PTZ Parameters Enter PTZ configuration menu: MAIN MENU > DOME SETTINGS > MOTION PARAMETER © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 23 It can also reduce the use of bandwidth in a digital network system. You can set IMAGE FREEZE on to enable this function. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 24: Configuring Presets

    A preset is a user-defined monitor position/point. You can simply call the preset number to change the monitor scene to the defined position. Steps: 1. Move the cursor to enter preset configuration submenu: MAIN MENU > DOME SETTINGS > PRESETS © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 25 (4) Click IRIS+ to inset the selected character from the letter/number/symbol list to the label. (5) Click FOCUS IN to exit the character lists and click IRIS+ again to confirm and exit the submenu. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 26: Configuring Patrols

    (2) Click the up and down direction buttons to select the number of the patrol which is to be configured. (3) Click IRIS+ again to confirm and exit edit mode of this column. Note: You can configure up to 8 patrols. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 27 32 presets in sequence for a patrol. Press IRIS+ to save the current settings or press IRIS- to cancel and return to the previous menu. Patrol Speed Table 3-2 Level Speed(° /s) Level Speed(° /s) Level Speed(° /s) © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 28: Configuring Patterns

    (1) Move the cursor to PATTERN NUM and click IRIS+ to enter edit mode. (2) Click the up and down direction buttons to select the number of the pattern which is to be configured. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 29 2 is deleted, pattern 3 and pattern 4 will be deleted as well.  Clear all the patterns Enter CLEAR PATTERN menu and click IRIS+ to delete all the defined patterns. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 30: Configuring Time Tasks

    (2) Click the left and right direction buttons to position the cursor to WEEK, START (H-M) and END (H-M). (3) Click the up and down direction buttons to select the specific day and time. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 31: Configuring Zones

    ZONES submenu. You can define a zone when the targeted surveillance scene is limited. Steps: 1. Move the cursor to enter the zone configuration submenu: MAIN MENU > DOME SETTINGS > ZONES © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 32: Clearing Ptz Control Settings

    You can clear all user-defined PTZ control settings, including presets, patrols, patterns, zones and time tasks. You can also clear privacy masks on this menu. Steps: 1. Enter the CLEAR SETTINGS menu: MAIN MENU > DOME SETTINGS > CLEAR SETTINGS © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 33: Configuring And Handling Alarms

    Steps: 1. Move the cursor to enter the alarm configuration submenu: MAIN MENU > DOME SETTINGS > ALARMS > ALARM SETTING © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 34: Configuring Alarm Parameters

    3.5.2 Configuring Alarm Parameters Purpose: © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 35: Configuring Auxiliary Alarm Output

    Configure the AUX Output Figure 3-26 2. Click IRIS+ to edit the status of the auxiliary outputs. You can set the alarm output type as OPEN (normally open) and CLOSE (normally closed). © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 36: Others

    1 2 3 4 5 6 START USING EDIT PASSWORD INPUT PW AG 1 2 3 4 5 6 DONE: OPEN QUIT: CLOSE BACK EXIT Set the Password Figure 3-27 © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 37: Configuring Line Synchronization

    Click IRIS+ to restore the dome settings to the default value as shown in below table; or click IRIS- to exit. Default Dome Settings Table 3-3 Parameters Default Value Dome address Baud rate 2400bps 120Ω matching resistance Soft address © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 38: Restoring Default Camera Settings

    Click IRIS+ to restore the camera settings to the default value; or click IRIS- to exit. Note: Camera settings include the lens settings and display settings. 3.6.5 Rebooting the Dome Enter MAIN MENU > REBOOT DOME and click IRIS+ to reboot the speed dome remotely. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 39: Appendix

    4Ω, the section al area of the grounding cable should be no less than 25mm2. For grounding instructions, please refer to the Installation Manual of Speed Dome. Lightning & Surge Protection Figure A- 1 © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 40: Appendix 2 Rs485 Bus Connection

    RS485 industry standard so that it will lead to some problems such as signal reflection, anti-jamming ability decline when the devices are © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 41 RS485 industry standard, in order to avoid those problems and improve the communication reliability. RS485 Distributor Figure A-5  FAQ of RS485 Bus © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 42: Appendix 3 24Vac Wire Gauge & Transmission Distance

    10%. For example, for a device with the rating power of 80VA which is installed at a distance of 35 feet (10m) away from the transformer, then the minimum wire gauge required is 0.8000mm. Wire Gauge Distance feet(m) Power (va) © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 43: Appendix 4 Table Of Wire Gauge Standards

    5-i nch High Speed Dome User Ma nual Appendix 4 Table of Wire Gauge Standards Cross-sectional Area Bare Wire Gauge Americ an Wire Gage (Brit ish)St andard Wire G auge Bare Wire (mm) © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 44 The pan/tilt movement and zoom actions of the speed dome can be controlled by the control keyboard, DVR, matrix, etc.  Label Display The on-screen label of the preset title, azimuth/elevation, zoom and other operations can be © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 45  Soft Baud Rate The baud rate of the speed dome can be configured by the menu without need of DIP switch settings. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.
  • Page 46 If the speed dome has dwelled at a zone without receiving any command over 4 minutes, this feature will enable the speed dome to perform panorama scanning within the zone. © Hikvision Digital Technology C o., Ltd. All Rights Reserved.