Traverse Function; My Function-S - Toshiba Tosvert VF-S15 Instruction Manual

Industrial inverter (for 3-phase induction motors)
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

Title
f910
f911  Step-out detection time
f912
f913  d-axis inductance
 PM control type
 Refer to section 6.25.2 about setting motor constants.
Note 1: When using an PM motor, consult your Toshiba distributor, since the inverter is not compatible with all
Note 2: The inverter may fail to detect step-out in some cases, because it uses an electrical method to detect
6

6.40 Traverse function

f980 : Traverse selection
f981 : Traverse acceleration time
f982 : Traverse deceleration time
f983 : Traverse step
f984 : Traverse jump step
 Refer to "Traverse control Instruction Manual : E6581877" for details.

6.41 My function-S

a900 to a977 : My function-S
 Refer to "My function-S Instruction Manual : E6581865" for details.
Function
Step-out detection current level
q-axis inductance
types of PM motors.
step-out. To avoid detection failures, you are recommended to install a mechanical step-out detector.
Adjustment range
1 - 150 (%)
0.00: No detection
0.01 - 2.55 (s)
0.01-650.0 (mH)
0.01-650.0 (mH)
0: Mode 0
1: Mode 1
2: Mode 2
3: Mode 3
4: Mode 4e
F-142
E6581926
Default setting
100
0.00
10.00
10.00
3