Toshiba Tosvert VF-S15 Instruction Manual page 172

Industrial inverter (for 3-phase induction motors)
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

[If momentary power failure occurs]
Input voltage
Internal DC
voltage level
Motor speed
Note 5: If momentary power failure occurs during deceleration stop,
power ride-through control will not be performed.
 An example of setting when f302=2
Input voltage
Motor speed
Deceleration stop
• Even after the recovery from an input power failure, the motor continues deceleration stop. If the voltage in the
inverter main circuit falls below a certain level, however, control will be stopped and the motor will coast.
• If the voltage in main circuit falls below main circuit undervoltage (moff) level at Non-stop control during power
failure, the motor will coast and inverter displays stop and 0.0 alternately. The motor continues coasting even
after power supply is restored.
Normal acceleration
Time
F-61
E6581926
6