Cisco GS7000 Installation And Configuration Manual page 97

Optical
Table of Contents

Advertisement

Parameter
Function
ThresholdA
Switching threshold,
input optical power at
input A
Hysteresis
Hysteresis Amplitude:
Amplitude
The value (in dB
relative to the
switching threshold)
above which the input
optical power must
rise for the switch to
begin the hysteresis
timer before restoring
primary switch
position. Only
applies if Revert is On.
Hysteresis
Hysteresis Time: The
Time
length of time, in
seconds, that primary
optical power must
remain above the
restore threshold
before switch is
allowed to revert to
primary position.
Only applies if Revert
is On.
Revert
On (1) allows switch
to revert to primary
position after optical
power restored. In
Off (0), switch will
remain in backup
(non-primary)
position.
Primary
Selects the primary
Optical Input
optical input
Switch
Selects the Normal
Position
switch position
OL-29936-01
Default
Values
Value
5.0
1.0
60
On(1)
Off(0)
On(1)
PathA(0)
PathA(0)
PathB(1)
PathA(0)
PathA(0)
PathB(1)
Optical Switch Module
Min
Max
Step
-10.0
14.0
0.1
0.5
9.5
0.1
0
600
1
na
na
na
na
na
na
na
na
na
Unit
dBm
dB
sec
na
na
na
75