Electric Circuit; Wiring Diagram - Sharp AY-X36RU Service Manual

Split type air conditioners
Hide thumbs Also See for AY-X36RU:
Table of Contents

Advertisement

AY-X36RU
AE-X36RU
Instruction
Symbol
WH
YE
RD
YEGN
VT
GN
NOTE: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model.
Indoor Unit
Outdoor Unit

ELECTRIC CIRCUIT

[1] WIRING DIAGRAM

Symbol Color or Name
White
Yellow
Red
Yellow/Green
Violet
Green
Please don't touch any
electronic component or
terminal when the machine is
running , stopping or has
been powered off for less
than 30 minutes to prevent
the risk of electric shock !
Symbol
Symbol Color or Name
BN
BU
BK
OG
CAP
COMP
Please don't touch any
electronic component or
terminal when the machine
is running,stopping or
has been powered off for
less than 3 minutes to
prevent electric shock !
4
Brown
Blue
Black
Orange
Jumper cap
Compressor
NOTE:
Motor ground only
applies to the
iron shell motor.