Importing Image Data, Edit Lists

Edit List File Format

Edit list files are text files with the ".edl" filename extension. Composition is as follows:
Header:
PIONEER-DVDRec-EDL 002 ENCODING=XXX
Entry:
Number Operation Type Parameter 1 Parameter 2 Parameter 3
The number of parameters differs depending on the type of operation involved. Numbers are consecutive
numerals beginning from 001.
Use a single-byte space (0x20) or tab (0x09) between [PIONEER-DVDRec-EDL] and [002]. Alternately, a carriage
return character (0x0A, 0x0D0A, 0x0D) may also be used.
The message ENCODING=XXX indicates the character encoding, and may be omitted.
The "XXX" represented here supports utf8, eucJP, Shift-JIS, and JIS7. If the command is omitted, utf8 will be
used as default encoding.
I IN/OUT Point Setting Entry
Number
Operation Type
NNN
REC
The IN/OUT point is set using time code format as follows: HH:MM:SS:FF
Post-REC action will indicate either STOP or PAUSE.
The final IN/OUT point setting entry in an edit list must always designate the post-REC action as STOP.
I Chapter Point Setting Entry
Number
Operation Type
NNN
CHP
The chapter point is designated using time code as HH:MM:SS:FF. The chapter point description must come
immediately below the IN/OUT point setting to which it is applied. Also, the Number value is given as that
given to the IN/OUT point setting entry.
I DVD-RW disc initialization
Number
Operation Type
NNN
INI
Initialization can be applied only at the head of an edit list entry.
I Finalize
Number
Operation Type
NNN
FNL
Finalizing can be applied only as the final entry of an edit list.
I Wait
Number
Operation Type
NNN
WAI
The wait command can be used within a list, to designate points necessary to change a VTR tape, etc.
If a comment is input, the comment will appear in the wait dialog.
If the comment is separated by a tab (0x09), it will appear split into two lines at the point of the tab.
I Designating the Encoding Parameter
Number
Operation Type
NNN
SET
Rate is R:n (n= 1-32)
Filter is F:n (n= 0-16)
This setting will continue to be reflected after EDL execution.
74
PRV-LX10
En
Parameter 1
Parameter 2
IN Point
OUT Point
Parameter 1
CHAPTER POINT
Parameter
Comment
Parameter 1
Parameter 2
Rate
Filter
Parameter 3
Post-REC action

Advertisement

Table of Contents
loading

Table of Contents