Mitsubishi Q00JCPU User Manual page 615

Q series, logic
Hide thumbs Also See for Q00JCPU:
Table of Contents

Advertisement

APPENDICES
ACPU
Special
Special
Special
Relay after
Relay for
Relay
Conversion
Modification
M9235
SM1235
----
M9236
SM1236
----
M9237
SM1237
----
M9238
SM1238
----
M9240
SM1240
----
M9241
SM1241
----
M9242
SM1242
----
M9243
SM1243
----
M9246
SM1246
----
M9247
SM1247
----
M9250
SM1250
----
M9251
SM1251
----
M9252
SM1252
----
M9253
SM1253
----
M9254
SM1254
----
M9255
SM1255
----
TableApp.11 Special relay
Name
Meaning
Local station,
remote I/O station
OFF : No errors
parameter error
ON : Error detection
detect status
Local station,
remote I/O station
OFF : No communications
initial
ON : Communications
communications
underway
status
Local station,
OFF : Normal
remote I/O station
ON : Abnormal
error
Local station,
remote I/O station
OFF : Normal
forward or reverse
ON : Abnormal
loop error
OFF : Online
ON : Offline, station-to-
Link status
stationtest, or self-
loopback test
Forward loop line
OFF : Normal
error
ON : Abnormal
Reverse loop line
OFF : Normal
error
ON : Abnormal
OFF : Loopback not being
Loopback
conducted
implementation
ON : Loopback
implementation
OFF : Reception
Data not received
ON : No reception
OFF : Reception
Data not received
ON : No reception
Parameters not
OFF : Reception
received
ON : No reception
OFF : Normal
Link relay
ON : Abnormal
OFF : Not being executed
ON : Forward or reverse
Loop test status
loop test execution
underway
OFF : RUN or STEP RUN
Master station
status
operation status
ON : STOP or PAUSE
status
OFF : RUN or STEP RUN
Local station other
status
than host station
ON : STOP or PAUSE
operation status
status
Local station other
OFF : Normal
than host station
ON : Abnormal
error
Details
Depends on whether or not a local or a remote I/O station
has detected any link parameter error in the master station
Depends on the results of initial communication between a
local or remote I/O station and the master station.
(Parameter communication, etc.)
Depends on the error condition of a local or remote I/O
station.
Depends on the error condition of the forward and reverse
loop lines of a local or a remote I/O station.
Depends on whether the local station is online or offline, or is
in station-to-station test or self-loopback test mode.
Depends on the error condition of the forward loop line.
Depends on the error condition of the reverse loop line.
Depends on whether or not loopback is occurring at the local
station.
Depends on whether or not data has been received from the
master station.
Depends on whether or not a tier three station has received
data from its master station in a three-tier system.
Depends on whether or not link parameters have been
received from the master station.
Depands on the data link condition at the local station.
Depends on whether or not the local station is executing a
forward or a reverse loop test.
Control is performed depending on whether the master
station is in the STOP or PAUSE mode.
Control is performed depending on whether a local station
other than the host is in the STOP or PAUSE mode.
Depends on whether or not a local station other than the host
is in error.
Appendix 1 Special Relay List
9
Corresponding CPU
10
11
QnA
App
- 20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents