Mitsubishi Q00JCPU User Manual page 601

Q series, logic
Hide thumbs Also See for Q00JCPU:
Table of Contents

Advertisement

APPENDICES
Number
Name
Presence/absence of
OFF : SFC program absent
SM320
SFC program
ON : SFC program present
OFF : SFC program not
Start/stop SFC
SM321
program
ON : SFC program executed
SFC program start
OFF : Initial start
SM322
status
ON : Restart
OFF : Continuous transition
Presence/absence of
SM323
continuous transition
ON : Continuous transition
for entire block
OFF : When transition is
Continuous transition
SM324
prevention flag
ON : When no transition
Output mode at block
OFF : OFF
SM325
stop
ON : Preserves
SFC device clear
OFF : Clear device
SM326
mode
ON : Preserves device
OFF : Hold step output
Output during end step
SM327
execution
ON : Hold step output held
OFF : Clear processing is
Clear processing
SM328
mode when end step
ON : Clear processing is not
is reached
Operation mode for
OFF : Asynchronous mode
SM330
low speed execution
ON : Synchronous mode
type program
Normal SFC program
OFF : Not executed
SM331
execution status
ON : Being executed
Program execution
management SFC
OFF : Not executed
SM332
program execution
ON : Being executed
status
ON indicates completion of
SM390
Access execution flag
intelligent function module
access
*1: This applies to the CPU of function version B or later.
*2: This applies to the CPU with serial No. of first 5 digits "04122" or later.
TableApp.3 Special relay
Meaning
• Turns ON when an SFC program is registered.
• OFF when an SFC program is not registered.
• Initial value is set at the same value as SM320.
(Goes ON automatically if SFC program is present.)
executed (stop)
• Turn this relay from ON to OFF to stop program
execution.
(start)
• Turn this relay from OFF to ON to resume program
execution.
• The SFC program starting mode in the SFC setting
of the PLC parameter dialog box is set as the initial
value.
AT initial start: OFF
At continued start: ON
Set the presence/absence of continuous transition for
not effective
the block where "Continuous transition bit" of the SFC
data device has not been set.
effective
• OFF during operation in the continuous transition
mode or during continuous transition, and ON when
executed
continuous transition is not executed.
• Always ON during operation in the no continuous
transition mode.
Select whether the coil outputs of the active steps are
held or not at the time of a block stop.
• As the initial value, the output mode at a block stop in
the parameter is OFF when the coil outputs are OFF,
and ON when the coil outputs are held.
• All coil outputs go OFF when this relay is OFF.
• Coil outputs are preserved when this relay is ON.
Selects the device status when the stopped CPU is run
after the sequence program or SFC program has been
modified when the SFC program exists.
• Select the device status at the time of switching from
turned OFF (cleared)
STOP to program write to RUN.(All devices except
the step relay)
Select whether clear processing will be performed or
not if active steps other than the ones being held exist
in the block when the end step is reached.?
• When this relay turns OFF, all active steps are
performed.
forcibly terminated to terminate the block.
• When this relay is ON, the execution of the block is
performed.
continued as-is.
• If active steps other than the ones being held do not
exist when the end step is reached, the steps being
held are terminated to terminate the block.
Select whether the low speed execution type program
will be executed in the asynchronous mode or in the
synchronous mode.
• Asynchronous mode (this relay is turned OFF.)
Mode in which the operation of the low speed
execution type program is performed continuously
within the excess time.
• Synchronous mode (this relay is turned ON.)
Mode in which the operation of the low speed
execution type program is not performed
continuously and operation is performed from the
next scan if there is excess time.
• Indicates whether the normal SFC program is being
executed or not.
• Used as an SFC control instruction execution
interlock.
• Indicates whether the program execution
management SFC program is being executed or not.
• Used as an SFC control instruction execution
interlock.
• The status of the intelligent function module access
instruction executed immediately before is stored.
(This data is overwritten when the intelligent function
module access instruction is executed again.)
• Used by the user in a program as a completion bit.
Set by
Explanation
(When Set)
S (Initial)
S (Initial)/U
S (Initial)/U
S (Instruction
execution)
S (Status change)
S (Initial)/U
S (Initial)/U
S (Status change)
S (Status change)
Appendix 1 Special Relay List
Corres-
ponding
Corresponding CPU
ACPU
M9
M9100
M9101form
at change
M9102form
at change
U
M9103
QnA
Q00J/Q00/Q01
Qn(H)
M9104
QnPH
QnPRH
New
M9196
U
New
New
U
U
New
Q00J/Q00/Q01
QnA
U
New
Qn(H)
QnPH
*2
Qn(H)
New
QnPRH
Qn(H)
New
QnPH
QnPRH
App
9
10
11
*1
*1
- 6