Probe - Standard
Length
350mm (14") to 1000mm (40")
Process Size (in inches)
NPT: ¾ , 1, 1¼, 1½
BSPT: ¾, 1, 1½
JIS:
1, 1½
Insulating Material
Standard Version:
High Temperature Version:
No insulation on active probe
Tensile kg load
Not applicable
Probe Diameter
19mm
Probe - Cable
Length
500mm (20") to 25000mm (985")
Process Size
NPT/BSPT: 1¼" minimum
Insulating Material
AISI 316L SS
PFA insulation optional
Tensile kg load
1900 kg (4188 lbs.)
Electrode Dimensions
Cable:
Weight:
Butterfly:
Approvals
CE, CSA, NRTL/C, FM, CENELEC
Please verify against device nameplate.
7ML19985CK03
Pointek CLS 300 – INSTRUCTION MANUAL
PFA
Ceramic
Insulated:
9mm (0.35"
Non insulated:
6mm (0.24"
32 x 250mm (1.26 x 9.84")
175 x168mm (6.89 x 6.61")