Power Supply and Transmitter
Supply Voltage
2 - 250 Vac/dc any polarity galvanically isolated
Power consumption
2VA/2Watt
Wiring connections
2
Max. 2.5mm
Temperature ranges
Operation (Storage):
Signal indicators
Three:
Adjustment Potentiometers
Two:
Adjustment Switches
5PST dip switch:
Min. Sensitivity
1% change in actual capacitance
Max. Temperature Drift
0.2% of Actual Capacitance Value
Measurement Frequency
600 (kHz) max.
ESD protection
Protected to 55kV continuous discharge
Output Functions
Relay Contact
Contact:
Max. Contact Load (dc):
Max. Contact Load (ac):
Max. Switching Capacity:
Min. Contact Load:
Time Delay (ON and/or OFF):
Solid State switch
Output:
Safety:
Max. Load:
Max. Switch Voltage:
Max. Load Current:
Voltage Drop
Time Delay (On and/or Off)
Two (2) Wire Switch
With customer supplied external trip devices
Page 4
Pointek CLS 300 – INSTRUCTION MANUAL
-40 to 85° C (-40 to 185° F)
1. Adjustment control
2. Output status
3. Power
1. Time delay adjustment
2. Sensitivity adjustment
time delay select
fail safe selection
time delay test/adjust
high/low sensitivity
Form C (SPDT) (selectable NC or NO contact)
5A/30V dc
8A/250V ac (cosn=1)
150Watt/2000VA
10mA/5Vdc
1 - 60 sec.
Galvanically isolated
Non-polarity sensitive transistor
2 Watt
250Vac/300Vdc
100mA
Below 1 Volt typical @ 50mA
1 - 60 sec.
7ML19985CK03