Vpc Domain - Dell N1100-ON Reference Manual

Table of Contents

Advertisement

console(config-if-Po3)#switchport trunk allowed vlan 1-99,101-4093
console(config-if-Po3)#vpc 2
console(config-if-Po3)#exitconsole(config)#interface po3
console(config-if-Po3)#switchport mode trunk
console(config-if-Po3)#switchport trunk allowed vlan 1-99,101-4093
console(config-if-Po3)#vpc 2
console(config-if-Po3)#exit

vpc domain

Use the vpc domain command to enter into MLAG configuration mode. This
command creates an MLAG domain and enters into MLAG configuration
mode. Use the no form of the command to delete the VPC domain, disable
peer-keepalive and peer detection in the domain, and reset all the configured
parameters (role priority, VPC MAC address and VPC system priority) for the
VPC domain.
Syntax
vpc domain domain-id
domain-id—The MLAG domain instance. The range is 1-255.
Default Configuration
By default, no MLAG domains are configured.
Command Modes
Global Configuration mode
User Guidelines
Only one MLAG domain per MLAG is supported. This command creates a
VPC domain with the specified domain-id and enters into the VPC domain
configuration mode. Only one VPC domain can be created on a given device.
The domain-id of the VPC domain should be equal to the one configured on
the other VPC peer with this device wants to form a VPC pair. The configured
VPC domain-ids are exchanged during role election and if they are configured
differently on the peer devices, then VPC does not become operational.
The administrator needs to ensure that the no two VPC domains share the
same VPC domain-id. The domain-id is used to derive the auto-generated
VPC MAC address used in the actor ID field in the LACP PDUs and STP
601