13 XNX Labels

13�1 UL Certification Labels
An explanation of the information on the XNX certification label is shown below.
Product Name
WARNING:
• TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERE CONDUIT RUNS MUST HAVE A SEAL FITTING CONNECTED WITHIN 18" [457mm] OF ENCLOSURE.
CAUTION:
• FOR SAFETY REASONS THIS EQUIPMENT MUST BE OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY. READ AND UNDERSTAND MANUAL PRIOR TO
SERVICING.
• HIGH OFF SCALE READING MAY INDICATE EXPLOSIVE CONCENTRATIONS.
• THIS AREA MUST BE FREE OF FLAMMABLE GASES DURING CALIBRATION.
AVERTISSEMENT:
• POUR REDUIRE LE RISQUE D' ALLUMAGE DANS L'ATMOSPHÈRE. LES CONDUITS DOIVENT AVOIR UN JOINT D'ÉTANCHÉITÉ INSTALLÉS À MOINS DE
ATTENTION:
18 " [457 mm] DU BOITIER.
• POUR DES RAISONS DE SECURITÉ, CET EQUIPMENT DOIT ETRE UTILISÉ, ENTRETENU ET REPARÉ UNIQUEMENT PAR UN PERSONNEL QUALIFIÉ SEULEMENT.
LIRE ET COMPRENDRE LE MANUEL D'INSTRUCTIONS AVANT UTILISATION.
• DES LECTURES HORS ECHELLE PEUVENT INDIQUER DES CONCENTRATIONS EXPLOSIVES
• CETTE ZONE DOIT ETRE EXEMPTE DE GAZ INFLAMMABLES PENDANT L'ETALONNAGE
User Warnings/Cautions
Product Name
WARNING:
• TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERE CONDUIT RUNS MUST HAVE A SEAL FITTING CONNECTED WITHIN 18" [457mm] OF ENCLOSURE
CAUTION:
• SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY.
• FOR SAFETY REASONS THIS EQUIPMENT MUST BE OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY. READ AND UNDERSTAND MANUAL PRIOR TO SERVICING
• HIGH OFF SCALE READING MAY INDICATE EXPLOSIVE CONCENTRATIONS.
• THIS AREA MUST BE FREE OF FLAMMABLE GASES DURING CALIBRATION.
AVERTISSEMENT:
• POUR REDUIRE LE RISQUE D' ALLUMAGE DANS L'ATMOSPHÈRE. LES CONDUITS DOIVENT AVOIR UN JOINT D'ÉTANCHÉITÉ INSTALLÉS À MOINS DE 18 " [457 mm] DU BOITIER
ATTENTION:
• LA SUBSTITUTION DES COMPOSANTES PEUT COMPROMETTRE LA SÉCURITÉ INTRINSÉQUÉ.
• POUR DES RAISONS DE SECURITÉ, CET EQUIPMENT DOIT ETRE UTILISÉ, ENTRETENU ET REPARÉ UNIQUEMENT PAR UN PERSONNEL
QUALIFIÉ SEULEMENT LIRE ET COMPRENDRE LE MANUEL D'INSTRUCTIONS AVANT UTILISATION
CONCENTRATIONS EXPLOSIVES
User Warnings/Cautions
13�2 ATEX Certification Label
An explanation of the information on the XNX ATEX certification label is shown
below.
Product Name
User Warnings/Cautions
Protection Concept
ATEX Coding
Additional Agency Approval
(configuration dependant
See
XNX Certifications
by Part Number
Series)
XNX Universal Transmitter Quick Start Guide
Additional Agency Approval
(configuration dependant
See
by Part Number
Figure 50. XNX Label for Non-IS Applications
• DES LECTURES HORS ECHELLE PEUVENT INDIQUER DES
• CETTE ZONE DOIT ETRE EXEMPTE DE GAZ INFLAMMABLES PENDANT L'ETALONNAGE
Additional Agency Approval
(configuration dependant
See
by Part Number
Figure 51. XNX Label for IS Applications
Temperature Class
Gas Group
ATEX Certificate Number
Figure 52. XNX Label for ATEX
XNX Unit Serial Number
XNX Unit Part Number
XNX-
Mfg'd by: Honeywell Analytics, Inc., 405 Barclay Blvd. Lincolnshire, IL 60069 USA
UL Approvals
XNX Certifications
Series)
XNX Unit Serial Number
XNX Unit Part Number
XNX-
Mfg'd by: Honeywell Analytics, Inc., 405 Barclay Blvd. Lincolnshire, IL 60069 USA
UL Approvals
XNX Certifications
Series)
XNX Unit Serial Number
Format: WW YY NNNN
(Week Year Unit)
XNX Unit Part Number
Equipment Protection Level
Ambient Range
(-20°C to 40°C unless stated on label)
Manufacturers Name and Address
Minimum Voltage Requirement
(16 for EC/mV and 18 for IR)
SN:
to 32 VDC Max.
XNX Universal Transmitter for use in Class I, Div. 1 Groups B,C & D
Class 1, Zone 1, Groups IIB+H2 Haz Loc. Tamb
°C to
°C Temp Code T4
Only as to Explosion, Fire, Electrical and Shock Hazard
When Installed Per XNX Manual
Relay Option XNX - UT  -R  or XNX-RLY
Contact Ratings: 250 VAC 5A, 24VDC 5A Resistive Loads Only
Manufacturers Name and Address
Minimum Voltage Requirement
(16 for EC/mV and 18 for IR)
SN:
to 32 VDC Max.
XNX Universal Transmitter for use in Class I, Div. 1 Groups B,C & D [Exia]
Class 1, Zone 1, Groups IIB+H2 Haz Loc. Tamb
°C to
°C Temp Code T4
Only as to Explosion, Fire, Electrical Shock Hazard and Intrinsic Safety
Associated Apparatus Providing Intrinsically Safe Circuits When Installed Per
XNX Manual and Control Drawing 1226E0402 Um=250V
Relay Option XNX - UT  -R  or XNX-RLY
Contact Ratings: 250 VAC 5A, 24VDC 5A Resistive Loads Only
Manufacturers Name and Address
Ingress Protection
ATEX Notified Body
Identification Number
Additional Agency Approval
(configuration dependant)
IECEx Certificate Number
Wattage Requirement
Class 2 Supply Req'd
R
35YL
Wattage Requirement
Class 2 Supply Req'd
R
35YL
Wattage
Requirement
71