CHAPTER 2. MMC Programming
Timer Name
CO CONFIRM TIME
CO-CO DISCONNECT
CONFIRM TONE TM
CRD TONE INT TM
DIAL PASS TIME
DISA DISCONNECT
DISA LOCK OUT TM
DISA NOANS DISC.
DISA PASS CHECK
DISA NO ACTION
DISPLAY DELAY TM
DOOR LOCK RELES.
DOOR RING DETECT
DOOR RING OFF TM
E-HOLD RECALL TM
Samsung Business Communications
Default
Range Unit
3
0-250 MIN
20
1-250 MIN
1000
100-2500
MSEC
30
0-250 SEC
3
0-25 SEC
30
1-250 MIN
30
1-250 MIN
30
0-250 SEC
30
1-250 MIN
10
0-250 SEC
2
1-250 SEC
500
100-2500
MSEC
50
10-250
MSEC
30
1-250 SEC
45
0-250 SEC
OfficServ 7200 Programming Guide
Description
According to MMC 314 CO CONFIRM type,
the outgoing call will be disconnected after
this timer expires or the outgoing caller will
hear the confirm tone.
This timer monitors the duration of an unsu-
pervised conference; when it expires, both
trunks are disconnected.
The tone heard when a feature is activated or
deactivated.
This is the call record tone interval time. An entry
other than zero will cause a tone to be heard by
all the parties in a recorded conversation. The
range for the tone is 001(every second) to 255
(every 255 seconds). A value of 000 means no
tone. Requires an SVMi card.
This timer monitors the time before connect-
ing the transmit of the phone to the trunk side
of an outgoing call.
This timer controls the maximum duration of a
DISA call.
This timer controls how long a DISA call is not
allowed to be made after the DISA error
counter has expired (MMC 500).
This timer determines when a DISA call is
disconnected by force when a called party
does not answer.
This timer defines the period before the sys-
tem clears the incorrect passcode counter.
This timer controls how long a DISA line will
wait for further action from the caller.
This timer controls how long a display is
shown in the LCD and how long error tone is
heard.
This timer controls how long the door lock
relay will be activated.
This timer controls the time before a call is
answered by the door phone.
This timer controls the duration of ringing at
the door ring destination before automatically
cancelling.
This timer controls how long a call is held ex-
clusively at a station before recalling.
2-141