Always disconnect the air hose and remove all of
•
the staples:
1.When unattended.
2.Before performing any maintenance or repair.
3.Before cleaning a jam.
4.Before moving the tool to a new location.
Perform cleaning and maintenance right after
•
finishing the job. Keep the tool in tip-top condition.
Lubricate moving parts to prevent rusting and
minimize friction-related wear. Wipe off all dust
from the parts.
Do not operate this tool if it does not contain a
•
legible WARNING LABEL.
Do not modify tool without authorization from
•
Makita.
Ask Makita's Authorized service centers for
•
periodical inspection of the tool.
To maintain product SAFETY and RELIABILITY,
•
maintenance and repairs should be performed by
Makita Authorized Service Centers, always using
Makita replacement parts.
Use only pneumatic tool oil specified in this
•
manual.
Never connect tool to compressed air line where
•
the maximum allowable pressure of tool cannot be
exceeded by 10 %. Make sure that the pressure
supplied by the compressed air system does not
exceed the maximum allowable pressure of the
fastener driving tool. Set the air pressure initially to
the lower value of the recommended allowable
pressure.
Do not attempt to keep the trigger contact element
•
depressed with tape or wire. Death or serious
injury may occur.
Always check contact element as instructed in this
•
manual. Staples may be driven accidentally if the
safety mechanism is not working correctly.
SAVE THESE INSTRUCTIONS.
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
・
Read instruction manual.
・
Wear safety glasses.
・
Do not use on scaffoldings, ladders.
INSTALLATION
Selecting compressor
(L/min.)
150
120
90
60
30
0
0
008431
(L /min.)
150
120
90
60
30
0
0
008430
Select a compressor that has ample pressure and air
END106-1
output to assure cost-efficient operation. The graph
shows
the
applicable pressure and compressor air output.
Thus, for example, if stapling takes place at a rate of
approximately 60 times per minute at a compression of
0.68 MPa (6.8 bar), a compressor with an air output over
90L/minute is required.
Pressure regulators must be used to limit air pressure to
the rated pressure of the tool where air supply pressure
exceeds the tool's rated pressure. Failure to do so may
result in serious injury to tool operator or persons in the
vicinity.
6
AT1150A
10
20
30
40
Stapling frequency (times/min)
AT2550A
10
20
30
40
Stapling frequency (times/min)
relation
between
stapling
50
60
50
60
frequency,