Installation - Makita AT1150A Instruction Manual

Medium and wide crown stapler
Hide thumbs Also See for AT1150A:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Always disconnect the air hose and remove all of
the staples:
1.When unattended.
2.Before performing any maintenance or repair.
3.Before cleaning a jam.
4.Before moving the tool to a new location.
Perform cleaning and maintenance right after
finishing the job. Keep the tool in tip-top condition.
Lubricate moving parts to prevent rusting and
minimize friction-related wear. Wipe off all dust
from the parts.
Do not operate this tool if it does not contain a
legible WARNING LABEL.
Do not modify tool without authorization from
Makita.
Ask Makita's Authorized service centers for
periodical inspection of the tool.
To maintain product SAFETY and RELIABILITY,
maintenance and repairs should be performed by
Makita Authorized Service Centers, always using
Makita replacement parts.
Use only pneumatic tool oil specified in this
manual.
Never connect tool to compressed air line where
the maximum allowable pressure of tool cannot be
exceeded by 10 %. Make sure that the pressure
supplied by the compressed air system does not
exceed the maximum allowable pressure of the
fastener driving tool. Set the air pressure initially to
the lower value of the recommended allowable
pressure.
Do not attempt to keep the trigger contact element
depressed with tape or wire. Death or serious
injury may occur.
Always check contact element as instructed in this
manual. Staples may be driven accidentally if the
safety mechanism is not working correctly.
SAVE THESE INSTRUCTIONS.
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
Read instruction manual.
Wear safety glasses.
Do not use on scaffoldings, ladders.

INSTALLATION

Selecting compressor
(L/min.)
150
120
90
60
30
0
0
008431
(L /min.)
150
120
90
60
30
0
0
008430
Select a compressor that has ample pressure and air
END106-1
output to assure cost-efficient operation. The graph
shows
the
applicable pressure and compressor air output.
Thus, for example, if stapling takes place at a rate of
approximately 60 times per minute at a compression of
0.68 MPa (6.8 bar), a compressor with an air output over
90L/minute is required.
Pressure regulators must be used to limit air pressure to
the rated pressure of the tool where air supply pressure
exceeds the tool's rated pressure. Failure to do so may
result in serious injury to tool operator or persons in the
vicinity.
6
AT1150A
10
20
30
40
Stapling frequency (times/min)
AT2550A
10
20
30
40
Stapling frequency (times/min)
relation
between
stapling
50
60
50
60
frequency,

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

At2550a

Table of Contents