Advertisement

GSMVLP4G Status Displays (Continued)
[S]
ECP
[T]
Test Msg Sent
[X]
Reset CPU Y/N
[↑]
Registering ...
(UP arrow)
[↓]
Enter PIN#
(DN arrow)
[0]
Force Server
Update?
Y/N
[ENTER]
Strt Prog Mode?
Y/N_
ECP Mode
Flt
Displays the mode of operation and system fault status.
OK
Test Alarm
Sends a Test alarm to AlarmNet. Functional for a registered
GSMVLP4G only. If the device is not registered, a message is
displayed indicating that the command cannot be executed.
Reset the GSMVLP4G.
Pressing [N] returns to normal mode.
Pressing [Y] resets the device.
Registration
Registers a programmed GSMVLP4G with AlarmNet.
Registration with PIN for Replacement Module
Registers a replacement GSMVLP4G with AlarmNet, once
programmed, using the existing PIN #.
Force Upload of Configuration File to Server
Pressing [Y] will force the device to upload its entire
configuration file to the server.
Pressing [N] cancels the operation.
NOTE: If the GSMVLP4G module is not initialized when you enter this
command, the following screen will be displayed:
Cannot Upload
Try Later! _
Wait for the RSSI LEDs to light, indicating the GSMVLP4G
module has completed its initialization, and try again.
Enter Program Mode
Press [Y] to enter program mode; otherwise, press [N].