Siemens SCALANCE XB-200 Web Based Management page 87

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

● E-mail
The device sends an e-mail. This is only possible if the SMTP server is set up and the
"SMTP client" function is enabled.
● Trap
The device sends an SNMP trap. This is only possible if "SNMPv1 Traps" is enabled in
"System > Configuration".
● Log Table
The device writes an entry in the event log table, see "Information > Log Table"
● Syslog
The device writes an entry to the system log server. This is only possible if the system log
server is set up and the "Syslog client" function is enabled.
● Fault
The device triggers a fault. The error LED lights up
Steps in configuration
1. Select the check box in the row of the required event. Select the event in the column
under the following actions:
– E-mail
– Trap
– Log table
– Syslog
– Fault
2. Click the "Set Values" button.
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02
Configuring with Web Based Management
5.4 The "System" menu