Siemens SIMATIC NET SCALANCE XB-200 Series Operating Instructions Manual

Siemens SIMATIC NET SCALANCE XB-200 Series Operating Instructions Manual

Industrial ethernet switches

Advertisement

SIMATIC NET
Industrial Ethernet Switches
SCALANCE XB-200
Operating Instructions
03/2020
C79000-G8976-C359-09
Introduction
Safety notices
Recommendations on
network security
Description of the device
Installation
Connecting up
Upkeep and maintenance
Technical specifications
Dimension drawings
Approvals
1
2
3
4
5
6
7
8
9
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET SCALANCE XB-200 Series

  • Page 1 Introduction Safety notices Recommendations on network security SIMATIC NET Description of the device Industrial Ethernet Switches SCALANCE XB-200 Installation Connecting up Operating Instructions Upkeep and maintenance Technical specifications Dimension drawings Approvals 03/2020 C79000-G8976-C359-09...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction..............................5 Safety notices ...............................9 Recommendations on network security......................11 Description of the device ..........................17 Product overview........................17 Device views ..........................20 4.2.1 SCALANCE XB208 ........................20 4.2.2 SCALANCE XB205-3......................21 4.2.3 SCALANCE XB213-3......................22 RESET button ........................23 LED display ..........................25 Installation ..............................27 Safety notices for installation ....................27 Mounting on DIN rails......................30 Connecting up ............................33 Safety when connecting up ....................33...
  • Page 4 Table of contents Technical specifications of the SCALANCE XB213-3LD (SC)..........59 Technical specifications of the SCALANCE XB213-3............61 Cable lengths .........................63 8.10 Switching properties.......................64 Dimension drawings ...........................65 Approvals..............................69 Index................................77 SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 5: Introduction

    Introduction Purpose of the Operating Instructions These operating instructions support you when installing and connecting up devices of the SCALANCE XB-200 product group. The configuration and the integration of the devices in a network are not described in these operating instructions. Validity of the Operating Instructions These operating instructions apply to the following devices: ●...
  • Page 6 You will find the configuration manuals here: ● on the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15291/man). Further documentation In the system manuals "Industrial Ethernet / PROFINET Industrial Ethernet"...
  • Page 7 Feed under http://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: ● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI ● SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 ●...
  • Page 8 Introduction Device defective If a fault develops, send the device to your SIEMENS representative for repair. Repairs on-site are not possible. Decommissioning Shut down the device properly to prevent unauthorized persons from accessing confidential data in the device memory. To do this, restore the factory settings on the device.
  • Page 9: Safety Notices

    Safety notices Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury, read the manual before use.
  • Page 10 Safety notices SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 11: Recommendations On Network Security

    Industrial Security (https://www.siemens.com/ industrialsecurity) website. ● Inform yourself regularly about security recommendations published by Siemens ProductCERT (https://www.siemens.com/cert/en/cert-security-advisories.htm). ● Only activate protocols that you require to use the device. ● Restrict access to the management of the device with rules in an access control list (ACL).
  • Page 12 Recommendations on network security ● The option of VLAN structuring provides protection against DoS attacks and unauthorized access. Check whether this is practical or useful in your environment. ● Use a central logging server to log changes and accesses. Operate your logging server within the protected network area and check the logging information regularly.
  • Page 13 Recommendations on network security Secure/non-secure protocols and services ● Avoid or disable non-secure protocols and services, for example HTTP, Telnet and TFTP. For historical reasons, these protocols are available, however not intended for secure applications. Use non-secure protocols on the device with caution. ●...
  • Page 14 Recommendations on network security ● Use the configuration options of the interfaces, e.g. the "Edge Type". ● Configure the receive ports so that they discard all untagged frames ("Tagged Frames Only"). Available protocols The following list provides you with an overview of the open protocol ports. The table includes the following columns: ●...
  • Page 15 Recommendations on network security Protocol Protocol/ Default port sta‐ Configurable Authentication Encryption Port number port EtherNet/IP TCP/44818 Closed ✓ UDP/2222 (Open with UDP/44818 EtherNetIP var‐ iants) DHCP UDP/67 Closed ✓ UDP/68 Port number can be configured via the WBM. SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 16 Recommendations on network security SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 17: Description Of The Device

    Description of the device Product overview Article numbers There are two variants of each device with different article numbers. The two variants differ only in their factory settings. All other properties are identical. Device Description Article number Article number (Ethernet/IP) (PROFINET) SCALANCE XB208 8 x 10/100 Mbps RJ-45 ports...
  • Page 18 Description of the device 4.1 Product overview PROFINET variants ● Industrial Ethernet protocol: PROFINET ● Base bridge mode: 802.1D transparent bridge ● Redundancy mechanism: Ring redundancy Device Factory setting ring ports SCALANCE XB208 and XB216 P0.1 and P0.2 SCALANCE XB205-3, XB205-3 (SC) and XB205-3LD (SC) P0.7 and P0.8 SCALANCE XB213-3, XB213-3 (SC) and XB213-3LD (SC) P0.15 and P0.16 ●...
  • Page 19 Description of the device 4.1 Product overview Unpacking and checking WARNING Do not use any parts that show evidence of damage If you use damaged parts, there is no guarantee that the device will function according to the specification. If you use damaged parts, this can lead to the following problems: ●...
  • Page 20: Device Views

    Description of the device 4.2 Device views Device views 4.2.1 SCALANCE XB208 The following figure shows an overview of the components of the SCALANCE XB208. ① Electrical ports with port LEDs ② Power supply with connector for grounding ③ Serial interface ④...
  • Page 21: Scalance Xb205-3

    Description of the device 4.2 Device views 4.2.2 SCALANCE XB205-3 The following figure shows an overview of the components of the SCALANCE XB205-3. ① Optical ports with port LEDs ② Power supply with connector for grounding ③ Serial interface ④ Electrical ports with port LEDs ⑤...
  • Page 22: Scalance Xb213-3

    Description of the device 4.2 Device views 4.2.3 SCALANCE XB213-3 The following figure shows an overview of the components of the SCALANCE XB213-3. ① Optical ports with port LEDs ② Power supply with connector for grounding ③ Serial interface ④ Electrical ports with port LEDs ⑤...
  • Page 23: Reset Button

    Description of the device 4.3 RESET button RESET button Position The "RESET" button is located on the rear of the SCALANCE XB-200. Figure 4-1 Position of the "RESET" button, for example on the SCALANCE XB213-3 Resetting the device to factory defaults NOTICE Previous settings If you reset, all the settings you have made will be overwritten by factory defaults.
  • Page 24 Description of the device 4.3 RESET button Requirement ● The device is in operation. ● The function "Restore Factory Defaults" is enabled for the RESET button. Note Reset despite disabled "RESET" button If you have disabled the "Restore Factory Defaults"function for the "RESET" button in the configuration, this does not apply during the startup phase, see section "Restoring the factory settings (Page 47)"...
  • Page 25: Led Display

    Description of the device 4.4 LED display LED display Fault LED "F" The fault LED "F" indicates the incorrect functioning of the device. LED color LED status Meaning The device is a turned off. Green The device has not detected a problem. The device has detected a problem.
  • Page 26 Description of the device 4.4 LED display SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 27: Installation

    Installation Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 50 °C.
  • Page 28 Installation 5.1 Safety notices for installation Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING The equipment shall only be used in an area of not more than pollution degree 2, as defined in EN/IEC 60664-1.
  • Page 29 Installation 5.1 Safety notices for installation Note During installation and operation, keep to the installation guidelines and safety notices described in this document and in the system manuals "Industrial Ethernet / PROFINET Industrial Ethernet" and "Industrial Ethernet / PROFINET passive network components". You will find information on the system manuals in the section "Introduction", under "Further documentation".
  • Page 30: Mounting On Din Rails

    Installation 5.2 Mounting on DIN rails Mounting on DIN rails Installation clearances Keep to the following minimum clearances so that the convection ventilation of the device is not blocked: ● Below at least 10 cm ● Above at least 10 cm Installation Figure 5-1 DIN rail mounting...
  • Page 31 Installation 5.2 Mounting on DIN rails Removal Figure 5-2 Removing from a DIN rail To remove the device from a DIN rail, follow the steps below: 1. Disconnect all connected cables. ① 2. Release the DIN rail locking mechanism by pressing down on the release button ②...
  • Page 32 Installation 5.2 Mounting on DIN rails SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 33: Connecting Up

    Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. WARNING The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals, or the power supply unit for the equipment power supply must comply with NEC Class 2, as described by the National Electrical Code (r) (ANSI / NFPA 70).
  • Page 34 Connecting up 6.1 Safety when connecting up WARNING EXPLOSION HAZARD You may only connect or disconnect cables carrying electricity when the power supply is switched off or when the device is in an area without inflammable gas concentrations. Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING...
  • Page 35: Industrial Ethernet

    Connecting up 6.2 Industrial Ethernet Industrial Ethernet Ring ports When shipped the ring ports are marked by a label. The labels are only clipped on and you can remove them if necessary. 6.2.1 Electrical Note Strain relief for the Ethernet cables In order to avoid mechanical stress on the Ethernet cables and resulting interruption of the contact, fasten the cables at a short distance from the connector using a cable guide or busbar.
  • Page 36 Connecting up 6.2 Industrial Ethernet MDI / MDI-X autocrossover With the MPI/MDI-X autocrossover function, the send and receive contacts of an Ethernet port are assigned automatically. The assignment depends on the cable with which the communications partner is connected. This means that it does not matter whether the port is connected using a patch cable or crossover cable.
  • Page 37: Optical

    Connecting up 6.2 Industrial Ethernet 6.2.2 Optical NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Take the following precautions to avoid functional impairments: ●...
  • Page 38: Wiring Rules

    Connecting up 6.3 Wiring rules Wiring rules When wiring use cables with the following AWG categories or cross sections. Wiring rules for ... Spring-loaded terminals connectable cable cross sec‐ without wire end ferrule 0.2 - 1.5 mm tions for flexible cables ... AWG: 24 - 14 with wire end ferrule with plastic 0.25 - 0.75 mm...
  • Page 39: Power Supply

    Connecting up 6.4 Power supply Power supply Notes on the power supply WARNING Incorrect power supply Never operate the device with AC voltage or DC voltage higher than 32 V DC. CAUTION Damage to the device due to overvoltage The connector of the external power supply is not protected against strong electromagnetic pulses that can, for example, result from lightning strikes or switching large loads.
  • Page 40 Connecting up 6.4 Power supply Position and assignment Figure 6-1 Position of the power supply, for example on the SCALANCE XB213-3 Contact Assignment Assignment Contact 24 VDC 24 VDC Ground Ground Functional ground Functional ground SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 41: Serial Interface

    Connecting up 6.5 Serial interface Serial interface Information on the serial interface ● Via the serial interface (RJ-11 jack), you can access the CLI of the device directly via an RS-232 connection (115200 8N1) without assigning an IP address. ● Access to the device is also possible independent of the Ethernet ports. ●...
  • Page 42 Connecting up 6.5 Serial interface Note Pin assignment of the RJ-11 jack on the device The RJ-11 jack on the device has a pinout to match the RJ-11 plug of the connecting cable mentioned above. SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 43: Functional Ground

    Connecting up 6.6 Functional ground Functional ground EMC disturbances are diverted to ground via the functional ground. This ensures the immunity of the data transmission. The functional ground must be implemented with low impedance. The connection of the functional ground must be established directly on the mounting plate or the DIN rail terminal. The IE switch has a terminal for functional ground, refer to the section "Power supply (Page 39)".
  • Page 44 Connecting up 6.6 Functional ground SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 45: Upkeep And Maintenance

    Upkeep and maintenance Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Pressing the "RESET" button To load new firmware, you require the "RESET" button. When pressing the button, remember the information in the section "RESET button (Page 23)".
  • Page 46 Upkeep and maintenance 7.1 Downloading new firmware using TFTP without WBM and CLI 7. Open a Windows command prompt and change to the directory where the file with the new firmware is located and then execute the following command : tftp -i <IP address>...
  • Page 47: Restoring The Factory Settings

    Upkeep and maintenance 7.2 Restoring the factory settings Restoring the factory settings NOTICE Previous settings If you reset, all the settings you have made will be overwritten by factory defaults. NOTICE Inadvertent reset An inadvertent reset can cause disturbances and failures in the configured network. With the "RESET"...
  • Page 48 Upkeep and maintenance 7.2 Restoring the factory settings SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 49: Technical Specifications

    Technical specifications Technical specifications of the SCALANCE XB208 The following technical specifications apply to the SCALANCE XB208. Technical specifications Attachment to Industrial Ethernet Quantity Connector RJ-45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed 10 / 100 Mbps Diagnostics interface Serial interface Quantity Connector...
  • Page 50: Technical Specifications Of The Scalance Xb205-3 (Sc)

    Technical specifications 8.2 Technical specifications of the SCALANCE XB205-3 (SC) Technical specifications of the SCALANCE XB205-3 (SC) The following technical specifications apply to the SCALANCE XB205-3 (SC). Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed 10 / 100 Mbps...
  • Page 51 Technical specifications 8.2 Technical specifications of the SCALANCE XB205-3 (SC) Technical specifications Housing material Polycarbonate (PC-GF10) Degree of protection IP20 Dimensions (W x H x D) 80 x 117 x 109 mm Weight 350 g Installation options Installation on a DIN rail Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 52: Technical Specifications Of The Scalance Xb205-3Ld (Sc)

    Technical specifications 8.3 Technical specifications of the SCALANCE XB205-3LD (SC) Technical specifications of the SCALANCE XB205-3LD (SC) The following technical specifications apply to the SCALANCE XB205-3LD (SC). Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed 10 / 100 Mbps...
  • Page 53 Technical specifications 8.3 Technical specifications of the SCALANCE XB205-3LD (SC) Technical specifications Degree of protection IP20 Dimensions (W x H x D) 80 x 117 x 109 mm Weight 350 g Installation options Installation on a DIN rail Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 54: Technical Specifications Of The Scalance Xb205-3

    Technical specifications 8.4 Technical specifications of the SCALANCE XB205-3 Technical specifications of the SCALANCE XB205-3 The following technical specifications apply to the SCALANCE XB205-3. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed 10 / 100 Mbps Optical connectors...
  • Page 55 Technical specifications 8.4 Technical specifications of the SCALANCE XB205-3 Technical specifications Housing material Polycarbonate (PC-GF10) Degree of protection IP20 Dimensions (W x H x D) 80 x 117 x 109 mm Weight 350 g Installation options Installation on a DIN rail Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 56: Technical Specifications Of The Scalance Xb216

    Technical specifications 8.5 Technical specifications of the SCALANCE XB216 Technical specifications of the SCALANCE XB216 The following technical specifications apply to the SCALANCE XB216. Technical specifications Attachment to Industrial Ethernet Quantity Connector RJ-45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed 10 / 100 Mbps Diagnostics interface Serial interface...
  • Page 57: Technical Specifications Of The Scalance Xb213-3 (Sc)

    Technical specifications 8.6 Technical specifications of the SCALANCE XB213-3 (SC) Technical specifications of the SCALANCE XB213-3 (SC) The following technical specifications apply to the SCALANCE XB213-3 (SC). Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed 10 / 100 Mbps...
  • Page 58 Technical specifications 8.6 Technical specifications of the SCALANCE XB213-3 (SC) Technical specifications Housing material Polycarbonate (PC-GF10) Degree of protection IP20 Dimensions (W x H x D) 120 x 117 x 109 mm Weight 500 g Installation options Installation on a DIN rail Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 59: Technical Specifications Of The Scalance Xb213-3Ld (Sc)

    Technical specifications 8.7 Technical specifications of the SCALANCE XB213-3LD (SC) Technical specifications of the SCALANCE XB213-3LD (SC) The following technical specifications apply to the SCALANCE XB213-3LD (SC). Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed 10 / 100 Mbps...
  • Page 60 Technical specifications 8.7 Technical specifications of the SCALANCE XB213-3LD (SC) Technical specifications Degree of protection IP20 Dimensions (W x H x D) 120 x 117 x 109 mm Weight 500 g Installation options Installation on a DIN rail Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 61: Technical Specifications Of The Scalance Xb213-3

    Technical specifications 8.8 Technical specifications of the SCALANCE XB213-3 Technical specifications of the SCALANCE XB213-3 The following technical specifications apply to the SCALANCE XB213-3. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed 10 / 100 Mbps Optical connectors...
  • Page 62 Technical specifications 8.8 Technical specifications of the SCALANCE XB213-3 Technical specifications Housing material Polycarbonate (PC-GF10) Degree of protection IP20 Dimensions (W x H x D) 120 x 117 x 109 mm Weight 500 g Installation options Installation on a DIN rail Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 63: Cable Lengths

    Technical specifications 8.9 Cable lengths Cable lengths The following cable lengths listed are valid for SCALANCE XB-200. Cable Permitted cable length IE TP torsion cable 0 to 45 m with IE FC Outlet RJ-45 + 10 m TP cord + 10 m TP cord IE TP torsion cable 0 to 55 m with IE FC RJ-45 Plug 180...
  • Page 64: Switching Properties

    Technical specifications 8.10 Switching properties 8.10 Switching properties The following switching properties listed are valid for SCALANCE XB-200. Switching properties Aging time Can be configured (default value: 30 seconds) Maximum frame size 1632 Max. number of learnable ad‐ 8192 dresses Response to LLDP frames Blocking Response to spanning tree...
  • Page 65: Dimension Drawings

    Dimension drawings Note Dimensions are specified in mm. Front view of the SCALANCE XB208 Figure 9-1 Width and height SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 66 Dimension drawings Front view of the SCALANCE XB205-3 (SC), XB205-3LD (SC), XB205-3 and XB216 Figure 9-2 Width and height based on the example of the SCALANCE XB205-3 SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 67 Dimension drawings Front view of the SCALANCE XB213-3 (SC), XB213-3LD (SC) and XB213-3 Figure 9-3 Width and height based on the example of the SCALANCE XB213-3 SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 68 Dimension drawings Side view of the SCALANCE XB-200 Figure 9-4 Depth SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 69: Approvals

    Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/cert). Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive.
  • Page 70 ● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/78381013) The SIMATIC NET products described in these operating instructions meet the requirements of the EU directive 2014/34/EU "Equipment and Protective Devices for Use in Potentially...
  • Page 71 Approvals Permitted types of protection The following types of protection are possible: ● nA ATEX classification: II 3G Ex nA IIC T4 Gc Certificate no.: KEMA 07ATEX0145 X The products meet the requirements of the following standards: – EN 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") –...
  • Page 72 Approvals The following types of protection are possible: ● nA IECEx classification: Ex nA IIC T4 Gc Certificate no.: DEK 14.0025X The products meet the requirements of the following standards: – IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") –...
  • Page 73 Approvals Applied standards: ● EN 61000‑6‑2 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments ● EN 61000‑6‑4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments You will find the current versions of the standards in the currently valid EC declaration of conformity.
  • Page 74 Approvals Report no. E240480 Note for Australia - RCM The product meets the requirements of the RCM standard. Applied standards: ● AS/NZS CISPR11 (Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement). ● EN 61000-6-4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments You will find the current versions of the standards in the currently valid RCM SDoCs (Self- Declaration of Conformity).
  • Page 75 ● "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/27069465) ● "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/84922825) ● "EMC Installation Guidelines" configuration manual (https://support.industry.siemens.com/...
  • Page 76 Approvals Note The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above. When operating the device with a communications partner that does not comply with these standards, adherence to the corresponding values cannot be guaranteed. SCALANCE XB-200 Operating Instructions, 03/2020, C79000-G8976-C359-09...
  • Page 77: Index

    Index Accessories, 19 Glossary, 7 Ambient temperature, 49, 50, 52, 54, 56, 57, 59, 61 Grounding, 20, 21, 22, 43 Approvals, 69 Article numbers, 17 Attachment to Industrial Ethernet, 49, 50, 52, 54, 56, 57, 59, 61 Housing, 49, 50, 52, 54, 56, 57, 59, 61 Autonegotiation, 36 AWG, 38 Installation, 49, 50, 52, 54, 56, 57, 59, 61...
  • Page 78 Index general, 9 Use in hazardous areas, 9, 27, 33 when connecting up, 33 Serial interface, 20, 21, 22, 41 SIMATIC NET glossary, 7 SIMATIC NET manual, 6 Spring-loaded terminal, 39 Startup phase, 24, 47 System manual, 6, 29, 75 Web Based Management (WBM), 45 Weight, 49, 50, 52, 54, 56, 57, 59, 61 Wiring, 38...

Table of Contents