Immediate Apply Mode; Deleting The Stored Configuration; Configuration Object Operations - ABB MotiFlex e180 Application Manual

Ethercat
Hide thumbs Also See for MotiFlex e180:
Table of Contents

Advertisement

Immediate apply mode

It is possible to override the normal behavior for valid on reset objects to allow objects
that are linked to parameters (keywords) to be written with immediate effect. This
provides improved usability in PLC programs since it allows parameter access via
objects. To enable immediate apply mode, set object CFG_ImmediateApply_BOOL
(3004). Parameter values set while in immediate apply mode are volatile and will be
reset to their default / configuration value after a reset. To save the object as a
configuration value, write the value 0x65766173 [evas/save] to object 1010:01.

Deleting the stored configuration

Write 0x64616F6C [daol/load] to 1011:01 to delete the stored configuration and set all
objects to their default values.

Configuration object operations

Set parameter
Get parameter
Set/Get object
Set/Get object with
immediate apply enabled
Set/Get configuration
Reset configuration
Apply configuration
PARAMETERSAVE
(write object 1010)
FACTORYDEFAULTS
(write object 1011)
OBJECT DICTIONARY
Default value
Configuration
Default value
value
Non-volatile
stored value
123
123
123
123
123
Start-up 31
PARAMETER
TABLE
Current value
Live value in
Value of object
profiler /
in RAM;
scheduler
changed locally
or by master
123
123
123
123
123
123
Mint
123
123
123
123

Hide quick links: