B1: Continuouspath Mode, Exact Stop, LookAhead
3.10 Data lists
3.10
Data lists
3.10.1
Machine data
3.10.1.1
General machine data
Number
Identifier: $MN_
10110
PLC_CYCLE_TIME_AVERAGE
10680
MIN_CONTOUR_SAMPLING_TIME
10682
CONTOUR_SAMPLING_FACTOR
10712
NC_USER_CODE_CONF_NAME_TAB
12030
OVR_FACTOR_FEEDRATE
12100
OVR_FACTOR_LIMIT_BIN
18360
MM_EXT_PROG_BUFFER_SIZE
3.10.1.2
Channelspecific machine data
Number
Identifier: $MC_
20150
GCODE_RESET_VALUES
20170
COMPRESS_BLOCK_PATH_LIMIT
20172
COMPRESS_VELO_TOL
20400
LOOKAH_USE_VELO_NEXT_BLOCK
20430
LOOKAH_NUM_OVR_POINTS
20440
LOOKAH_OVR_POINTS
20443
LOOKAH_FFORM
20450
LOOKAH_RELIEVE_BLOCK_CYCLE
20460
LOOKAH_SMOOTH_FACTOR
20462
LOOKAH_SMOOTH_WITH_FEED
20465
ADAPT_PATH_DYNAMIC
20480
SMOOTHING_MODE
20482
COMPRESSOR_MODE
20488
SPLINE_MODE
20490
IGNORE_OVL_FACTOR_FOR_ADIS
20550
EXACT_POS_MODE
20560
G0_TOLERANCE_FACTOR
20600
MAX_PATH_JERK
20602
CURV_EFFECT_ON_PATH_ACCEL
20603
CURV_EFFECT_ON_PATH_JERK
212
Description
Average PLC acknowledgment time
Minimum contour sampling time
Contour sampling factor
List of reconfigured NC commands
Evaluation of the path feed override switch
Limit for binarycoded override switch
FIFO buffer size for execution from external source
(DRAM)
Description
Initial setting of the groups
Maximum traversing length of NC block for
compression
Maximum permissible deviation from path feed for
compression
LookAhead following block velocity
Number of override switch points for LookAhead
Override switch points for LookAhead
Activating the extended LookAhead
Relief factor for the block cycle time
Smoothing factor for LookAhead
Smoothing with programmed feed
Adaptation of path dynamic response
Rounding behavior with G64x
Compressor mode
Setting for spline interpolation
G641/G642 independent of the overload factor
Exact-stop conditions with G0/G1
G0 tolerance factor
Pathrelated maximum jerk
Influence of path curvature on path dynamic response
Influence of path curvature on path jerk
Function Manual, 09/2011, 6FC5397-0BP40-2BA0