OPERATION

1. Exhaust cover
8
To drive a nail, you may place the contact element against the workpiece and
007188
pull the trigger.
CAUTION:
WITH THE TRIGGER HELD IN A HALF-PULLED POSITION, an
unexpected nailing could occur, if contact element is allowed to re-
contact against the workpiece or the other surface under the influence of
recoil.
In order to avoid this unexpected nailing, perform as follows;
A. Do not place the contact element against the workpiece with excessive
force.
B. Pull the trigger fully and hold it on for 1-2 seconds after nailing.
Direction of exhaust air
007189
1
The direction of exhaust air can be changed 360 degrees of angle by turning
the exhaust cover with a hand.
Removing nails
CAUTION:
Do not use deformed nails or nail strip. Failure to do so causes poor nail
feeding.
WARNING:
Always disconnect the hose before removing nails.
Open the slide door and remove nails from the magazine.
007190
With the slide door kept open, open the door and take out nails.