ISSUE 3.0
4.
Turn the power switch ON at the Main KSU.
5.
Continue holding the LOAD button (S1) for approximately three seconds or until Status LED (D5)
starts flashing red.
6.
Release the LOAD button.
7.
When the system has completed reloading the software (about two minutes), the RUN LED is
flashing blue on the CPU card and the connected Multiline Telephone's display will show the Time
& Date and Extension Number.

1.2.2 Perform a Hot Start

This section describes how to load system software from flash memory, and the customer data from
RAM memory.
System software is loaded from flash memory, and the customer data is loaded
from RAM memory.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main KSU.
To perform a Hot Start;
1.
Turn the system power off.
2.
After it has powered off, turn the power switch back to ON. Wait approximately two minutes.
3.
When the system has completed reloading the software, the RUN LED is flashing blue on the
CPU card, and the connected Multiline Telephone's display will show the Time & Date and
Extension Number as
Hardware Manual
RUN LED

Figure 3-4 Status LED (D5) and RUN LED Location

Figure 3-5 Display Indication (Idle)

Figure 3-5 Display Indication (Idle) on page
LED (D5)
< Front view >
TUE18 7:27PM
200
3-3.
SL1000
3-3