Type 08
24-hour
Auxiliary Alarm
Type 09
Supervised
Fire
5806/5807/5808
01000-020-V0
Type 10
Interior w/Delay
Type 16
Supervised
Fire with
5806
Verification
06000-020-V0
Type 20
Arm–Stay
Type 21
Arm–Away
Type 22
Disarm
Type 23
No Alarm Response
Type 24
Silent Burglary
Zone Response Type Definitions
Zone type 08 is usually assigned to a zone containing a button for use in personal
emergencies or to a zone containing monitoring devices (i.e.: water or temperature
sensors, etc.).
Zone Characteristics:
• Sends a report to the central station and provides an alarm sound at the keypad. (No
bell output is provided and there is no keypad timeout.)
Zone type 09 can be assigned to any wireless zone used as a fire zone. This zone type is
always active and cannot be bypassed.
Zone Characteristics:
• Bell output will pulse when this zone type is alarmed.
Zone type 10 is bypassed when the panel is armed in STAY or STAY NO DELAY mode.
Zone Characteristics:
• Entry delay #1 (with programmed entry time) when armed in the AWAY mode.
• Entry delay begins whenever sensors in this zone are violated, regardless of whether
an entry/exit delay zone was tripped first.
• No entry delay when armed in the AWAY NO DELAY mode.
• Exit delay regardless of the arming mode selected.
Zone type 16 can be assigned to any wireless zone. It can not be used with heat
detectors, combination heat/smoke detectors, wireless sensors or fire pull
stations. This zone type is always active and can not be bypassed.
Zone Characteristics:
• Provides a fire alarm when zone is alarmed, but only after the alarm has been
verified.
• System verifies alarm by delaying reporting and control panel alarm sounding for 30
seconds after alarm is detected. If the zone remains faulted after 30 seconds a fire
alarm is provided. If any other fire zone is faulted during the 30 second delay window
a fire alarm is immediately provided for that zone. An alarm for original fire zone will
also be provided if that zone is still faulted afterward. If there are no fire alarms after
the 30 second delay expires, the system will open a 60 second window. If any fire zone
is faulted during that window a fire alarm will immediately be provided for that zone.
Bell output will pulse following alarm verification
Zone type 20 is a special-purpose zone type used with 5800 Series wireless pushbutton
units.
Zone Characteristics:
• Exit delay regardless of the arming mode selected.
• System is armed in the STAY mode when the zone is activated.
• Zone number is sent to the central station as a user number when arming or
disarming.
Zone type 21 is a special-purpose zone type used with 5800 Series wireless pushbutton
units.
Zone Characteristics:
• System is armed in the AWAY mode when the zone is activated.
• Zone number is sent to the central station as a user number when arming or
disarming.
Zone type 22 is a special-purpose zone type used with 5800 series wireless
pushbutton.
Zone Characteristics:
• Disarms the system when the zone is activated.
Zone type 23 can be used on a zone when a Powerline Carrier Device (e.g., X10) action
is desired, but with no accompanying alarm (e.g., front door light).
Zone type 24 is usually assigned sensors or contacts on exterior doors and windows
where bells and/or sirens are NOT desired.
Zone Characteristics:
• Instant alarm, with NO audible indication when is armed in the AWAY, STAY,
STAY NO DELAY, or AWAY NO DELAY mode.
• Report sent to the central station.
Note: Keypad beeps if the zone is faulted when system is disarmed and Chime mode is on.
- 19 -