Troubleshooting continued-
LED Status
Six flashes‐two 
flashes, three second 
pause (Soft lockout) 
Six flashes‐three 
flashes, three second 
pause (Soft lockout) 
Six flashes‐four 
flashes, three second 
pause (Soft lockout) 
Seven flashes, three 
second pause 
Eight flashes‐one 
flash, three second 
pause 
Eight flashes, two 
flashes, three second 
pause 
Eight flashes‐three 
flashes, three second 
pause 
Eight flashes‐four 
flashes, three second 
pause 
Control Status
Pressure switch or 
blower temperature 
switch opened 
during burner 
operation. 
System auto resets 
after 5 minutes. 
Pilot flame 
extinguished. 
System resets after 5 
minutes. 
Undesired‐false pilot 
flame sensed. 
System auto resets. 
Flammable vapor 
sensor fault 
detected, see 
warning label 
Flammable vapor 
sensor out of 
specification. 
Possible short. 
Temperature sensor 
fault 
Electronics fault 
detected 
Gas valve fault 
detected. 
Probable Cause
1. Pressure switch tubing kinked or blocked. 
2. Vent blockage or improper vent configuration. 
3. Vent termination being affected by windy 
conditions. 
4. Blower not spinning up to speed. 
5. Vent temperature too high. 
6. Faulty pressure switch or blower temp. switch. 
1. Unstable pilot. 
2. Pilot tube blocked or restricted. 
3. Oxidation build up on pilot electrode. 
4. Wire damage to pilot assembly or bad 
connection at gas valve. 
5. Insufficient combustion air. 
Pilot valve stuck in open position. 
1. Flammable vapor present 
2. Flammable vapor sensor exposed to excessive 
moisture 
3. Flammable vapor sensor exposed to extreme 
ambient temp 
1. Flammable vapor sensor out of specification 
2. Possible short. 
1. Damage to sensor or wire in control's well. 
2. Control's sensor resistance out of range. 
3. Replace control. 
1. Verify control is not wet or physically damaged 
2. Reset control on/off switch. 
3. Replace electronic module if 8‐3 error persists 
1. Verify control is not wet or physically damaged. 
2. Reset control on/off switch. 
3. Replace gas control if 8‐4 error persists 
41