Troubleshooting Of Sflow Statistics (Flow Statistics) Function; Sflow Packets Do Not Reach Collector - NEC IP8800/S2400 Series Troubleshooting Manual

Nec electronics america network hardware user manual
Table of Contents

Advertisement

3.
Troubleshooting Functional Failures in Operation
3.15 Troubleshooting of sFlow Statistics (Flow Statistics)
Function
The flow for troubleshooting of sFlow statistics function in this system is as follows.
Figure 3-18: Troubleshooting Flow of sFlow Statistics Function
Checking route to the collector.
Checking operation status by operation
command.
Checking configuration.
Checking failures etc.
3.15.1

sFlow Packets Do Not Reach Collector

(1) Checking route to the collector
See
"3.6.1 Communication Is Disabled or Is
to check to see if the collector is properly connected to network. If the maximum size of sFlow packets
(max-packet-size) is changed with the configuration, check to see if the connection to the collector can be established
with the specified packet size.
(2) Checking operation status by operation command
Execute the show sflow command several times to display the sFlow statistical information and check to see if
sFlow statistics function operates normally. If the underlined values shown below are not incremented, see
"(3)Checking
configuration." If incremented, see
3.9.1 Communication Is Disabled or Is
collector is properly connected to network.
Figure 3-19: Display Example of show sflow Command
> show sflow
Date 2006/10/24 20:04:01 UTC
sFlow service status: enable
Progress time from sFlow statistics cleared:
sFlow agent data :
sFlow service version
CounterSample interval rate: 60 seconds
Default configured rate: 1 per 2048 packets
Default actual rate
Configured sFlow ingress ports :
Configured sFlow egress ports
Received sFlow samples : 37269
112
Disconnected" and
"3.9.1 Communication Is Disabled or Is
"3.6.1 Communication Is Disabled or Is
Disconnected" and
"(5)Checking settings of
: 4
: 1 per 2048 packets
1/ 2-4
:
5/ 9-11
Dropped sFlow samples(Dropped Que) :
Disconnected," "
collector" to check to see if the
16:00:05