Makita LD100P Instruction Manual page 38

Hide thumbs Also See for LD100P:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 26
Press to stop continuous measurement (2). The
result is displayed in the summary line, the partial
results in the secondary line.
Indirect Measurement - determining a dis-
tance using 3 measurements
See figure {N}
Press this button twice; the display shows the
following symbol
. The laser is switched on.
Aim at the upper point (1) and trigger the
measurement. After the first measurement the value
is adopted. Keep the instrument as horizontal as
possible
Press and hold down this button to trigger
continuous measurement, sweep the laser up and
down over the ideal target point.
Press to stop continuous measurement (2). The
value is adopted. Aim at the lower point and
press this button to trigger the measurement
(3). The result is displayed in the summary line, the
partial results in the secondary lines.
Makita LD100P
Indirect measurement - determining a chain
value using 3 measurements
See figure {O}
e.g. determining the height between point 1 and
point 2 using three target points.
Press this button three times ; the display
shows the following symbol
switched on.
Aim at the upper point (1).
Press this button and trigger the measurement.
After the first measurement the value is adopted. The
display flashes (2).
Triggers the measurement. After the second
measurement the value is adopted. The display
flashes (3).
Press and hold down this button to trigger
continuous measurement. Sweep the laser up and
down over the ideal target point.
Press this button to end continuous measure-
ment. The result is displayed in the summary line, the
partial results in the secondary lines.