  • Page 1 OPERATION AND INSTALLATION INSTRUCTIONS WATER HEATER MODEL BMU 60 ADVANCED ENGINEERING FROM GERMANY...
  • Page 2 This water heater must be installed (water and electrical installation), commissioned and serviced by approved service technicians in accordance with these instructions. General information The chapter Operation is intended for users and quilified installers. The chapter Installation is intended for quilified installers. Please read carefully Read these instruction carefully before using the...
  • Page 3: Installation Instructions

    1. Installation instructions for the qualitified installer Functions Fixing method Pipework Installation Fig 1 Fig 3 Dimension Electrical connection Fig 2 Fig 4...
  • Page 4 1. Installation instructions for the qualitified installer Description of the unit Fig 5 Wiring Diagram Fig 6...
  • Page 5 Installation instructions for the user and the qualitified installer 1. Description of the unit permitted. The BMU flow-controlled instataneous - Safety valves are not required. water heater heats the water while it is Additional Safety. flowing trough the unit. The heating power is switched on automatically in the event of If for any reason, excessive heating the minimum flow rate being exceeded.
  • Page 6 Installation instructions for the user and the qualitified installer 8. Straighten the unit and tighten the screws. 6. Installation location 9. Connect the electrical supply. 10. Fit the cover and secure with the screw. The unit is to be installed in a 11.
  • Page 7 Installation instructions for the qualitified installer 10. Technical Data Type Design Flow switch type Rate content Water connection G 1/2” (External thread) Electrical connection 1/N/PE ~ 220...240 V. Recomended circuit breaker Recomended cable size (Spmm) Rated power (kW) Rate current (A) kW-A 220 V 60 - 27.3...
  • Page 8: Troubleshooting

    Installation instructions for the user and the qualitified installer 11. Guarantee The company does not accept liability For guarantees please refer to the respec- for failure of any good supplied which tive terms and conditions of supply for have not been installed and operated your country.
  • Page 12 SIZE:A5 MATERIAL: GREEN READ PAPER 75 G. PLASTIC BAG : 7 x 11 INCH PART NO. 7901-269462 PART NAME : MANUAL BMU Rev.03 Product code : BMU 60 : 220841...