17 When no more water comes out of the appliance, reinsert the EASY DECALC knob and turn it
clockwise to fasten it.
Storage
31
32
Troubleshooting
This chapter summarises the most common problems you could encounter with the appliance. If you are
unable to solve the problem with the information below, visit www.philips.com/support for a list of
frequently asked questions or contact the Consumer Care Centre in your country.
8
Put the appliance back on a stable and even surface. Plug in the appliance
and switch it on (Fig. 29).
9
Fill the water tank.
10 Wait for 5 minutes for the appliance to heat up.
11 Switch off DynamiQ function by pressing the intelligent automatic steam
button on the top of the iron handle.
12 Keep the steam trigger pressed continuously while you move the iron on a
piece of thick cloth for 3 minutes (Fig. 30).
Warning: Hot, dirty water comes out of the soleplate.
13 Stop moving the iron when no more water comes out.
14 Unplug the appliance after the descaling is completed and let it cool down
for at least two hours.
15 Hold a cup (with a capacity of at least 900ml) under the EASY DE-CALC
knob and turn the knob anticlockwise.
16 Remove the EASY DE-CALC knob and let the water with scale particles flow
into the cup.
1
Switch off the appliance and unplug it.
2
Put the iron on the iron platform. Push the carry lock to lock the iron onto
the platform.
3
Remove the water tank and empty it.
4
Wrap the steam supply hose around the base.
5
Slot it into the supply hose storage compartment by pushing the hose
through the gap (Fig. 31).
6
Fold the mains cord with the velcro provided, and insert it into the cord
storage compartment (Fig. 32).
7
You can carry the appliance with one hand by the handle of the iron.
Note: Do not carry the appliance by holding the water tank release lever
Note: If there is calc/fibre build up around the ActiveSense camera, remove
it gently with a cotton swab or equivalent.