Error Code - Samsung B421 Manual

Table of Contents

Advertisement

Available languages

Available languages

Error Code

Error Code
General Functions
TEMP SENSOR OPEN
In case the value of a temperature sensor is more than 250 °C during
operation / cancellation
TEMP SENSOR SHORT
In case the value of a temperature sensor is less than 5 °C during
operation / cancellation
OVER 210 °C DURING OPERATION OF MWO
In case the temperature rises over 210 °C during operation of MWO
(FIRE sensed)
DAMPER S/W
In case it fails to sense DAMPER whether to open or close for 2
minutes
47
B421_HAC_DE68-03150R-01_EN.indd 47
26/12/2012 11:56:10

Advertisement

Table of Contents
loading

Table of Contents