Chapter 10 Maintenance Using V-Tool
10.1 Maintenance Function
Maintenance functions possible by the combination of V-Tool and FL654 are as follows.
Download Function
Memory Clear Function
Version Read-out Function
Event Log Read-out Function
Operation Mode Setting
Calendar/Time Setting
LAN Management Information
10.1.1 Download Function
The FL654 recognizes I/O configuration information that is downloaded using V-Tool.
The FL654 setup procedure is described in Chapter 9, Startup Using V-Tool. This chapter
describes the download procedure using V-Tool.
(1) Select the relevant module (FL654) in the system's station configuration of the V-Tool
10
(2) Then the Download screen appears. Click the Download button.
66
and right click on it to display a menu.
In this menu, select "Module Parameter."
(See the Module Parameter screen in 9.1.4, Download, of Chapter 9, Startup Using
V-Tool.)
Operate direct connection of
FL654 and V-Tool
Available
Available
Available
Available
Available
Available
Available
Model 2000 FL-net (OPCN-2) Remote I/O Station Module (FL654) User's Manual
Operate other remote I/O
station via FL-net
Available
Available
Available
Available
Available
Available
Available