When the configuration is complete select the Finish button to Commit, Discard or Commit
Later. Select the Back button to return to the previous menu.
(Main Menu > Configure > Layout > Edit > Settings)
Use this menu to set up the layout settings for the screens.C
43-TV-25-35 GLO Iss.4 Dec 06 UK
A5E01001767-04
• • Charts, DPMs and Scales - Select which pen is displayed. Select and activate
which scale is required to be displayed.
• Showing (Pens) - Depending on the Template Type selected, choose Pens, Scales,
Max/Min values or Totals, depending on what is set up to be displayed. Multiple Scales
can be displayed by selecting more than one scale
• Orientation - (Not on the DPM screen). Set the orientation to Vertical or Horizontal for
Scales and Charts.
• Cycle Scales - (active with chart and scale combination). If ticked, the recorder will
cycle through each pen in the form of a scale or bar chart depending on which is
selected for the Scale Indicator .
• Scale Indicator - (active with chart and scale combination). Select which indicator,
either bar or pen pointers, will indicate on the scale.
• Background - Background colour can be set if no template is used. Select and choose
from the Colour palette.
Add Screen
• To add a new screen just select Add Screen and configure as required.
Delete Screen
• To Delete a screen just select Delete Screen to produce a list of current screens. Select
the screen to delete and it will be removed immediately.
Settings
• Cycle Screens - Tick this to cycle though each of the recorder's screens
• Cycle List - Select which screens you wish to be cycled
• Cycle Interval - Enter the amount of time, in seconds, that each of the cycle screens
are displayed for. (range 5 to 3600 seconds)
• Screen Hold - This will hold a selected screen for the amount of time specified before
returning to the cycle screens function. (range 0 to 3600 seconds)
• Alarm Screen - Select which screen is to be displayed when any pen goes into an
alarm state. Only changes colour if Mark on Chart is enabled in the
on page 66
• Alarm Screen Name - Only active if Alarm Screen is enabled
• Replay Screen TO (TimeOut) - If the recorder is in replay mode and there has not been
any user activity for a defined amount of time then the replay screen will return to the
process screen.
• Replay TimeOut - (only active if Replay Screen TO is enabled) Enter how long, in min-
utes, before the replay screen returns to a process screen. Defaults to 10 minutes.