Code
Description
14,79
Run-time error
14,80
Index out of bounds
14,81
Invalid argument
14,82
Invalid channel
14,83
Invalid command
14,84
Invalid command
opCode
14,85
The operation is not
implemented
14,86
Timeout
14,87
Resource already in use 1. Cycle power.
14,88
The dual-port memory is
corrupted
14,89
No valid ISR callback
routine set
14,90
An internal queue has
overflowed
14,91
Address not properly
aligned
14,92
Message too big for
queue
14,93
Data unit size violation
14,94
Checksum bad
14,95
PMD Host IO Error
14,96
Unidentified interrupt
occurred
14,97
Invalid data type
14,98
Find home failed, X EOT
timeout
14,99
Find home failed, Y EOT
timeout
Corrective Actions
1. Cycle power.
2. Check .cfg File for other errors.
3. Replace single board computer.
4. Replace controller board.
1. Cycle power.
1. Cycle power.
1. Cycle power.
1. Cycle power.
1. Cycle power.
Software error; will not be displayed.
1. Cycle power.
2. Replace controller board.
1. Cycle power.
1. Cycle power.
1. Cycle power.
1. Cycle power.
1. Cycle power.
1. Cycle power.
1. Cycle power.
2. Check 5/12 VDC power (5 and 12VDC
LEDs will repeatedly dim). Replace 5/12
VDC power supply.
3. If error code is displayed again within 3
months, replace controller board.
1. Cycle power.
1. Cycle power.
1. Cycle power.
1. Power cycle machine - remember to move
head away from switches.
2. Using LED's check to see limit box toggles
when switch is activated. If not, check
switch and/or umbilical cable for X, Y
cable for Y.
3. X errors - Check pins and reseat connector
J505 on the I/O board. Y errors - Check
pins and reseat connector J503 on the I/O
Card.